3
English
2-1 PRECAUTIONS
•
Be sure to read this manual before installing the indoor unit.
•
Entrust installation to the place of purchase or a qualified serviceman.Improper installation could lead to
leaks and, in worse cases, electric shock of fire.
•
Use only parts provided with the unit or parts satisfing required specifications. Unspecified parts could
cause the unit to fall out of place, or could lead to leaks and, in worse cases, electric shock or fire.
•
Do not install or operate the unit in rooms mentioned below.
• Laden with mineral oil, or filled with oil vapor or spray like in kitchens. (Plastic parts may
deteriorate which could eventually cause the unit to fall out of place, or could lead to leaks.)
• Where corrosive gas like sulfurous gas exists. (Copper tubing and brazed spots may corrode,
which could eventually lead to refrigerant leaks.)
• Where volatile flammable gas like thinner or gasoline is used.
• Where exposed to combustible gases and where voltatile flammable gas like thinner or gasoline
is used. (Gas in the vicinity of the unit could ignite.)
• Where machines can generate electromagnetic waves. (Control system may malfunction.)
• Where the air contains high levels of salt such as that near the ocean and where voltage
fluctuates greatly such as that in factories. Also in vehicles or vessels.
•
When selecting installation site, refer to the installation pattern.
•
This unit, both indoor and outdoor, is suitable for installation in a commercial and light industrial
environment. If installed as a household appliance it could cause electromagnetic interference.
2-2 ACCESSORIES
Check the following accessories are included with your unit.
2-3 OPTIONAL ACCESSORIES
•
These are two types of remote controllers: wired and wireless. Select a remote controller according to
customer request and install in an appropriate place.
•
If the customer wishes to use a remote controller that is not listed above, select a suitable remote
controller after consulting catalogs and technical materials.
Name
(1) Installation
panel
(2) Attachment screws
for the installation panel
(3) Paper pattern
for installation
(4) Insulating tape
Quantity
1 set
8 pcs.
→
FXA(Q)20,25,32 type
9 pcs.
→
FXA(Q)40,50,63 type
1 pc.
1 pc.
Shape
M4 × 25L
Name
(5) Clamp
(6) Securing screws
(Other)
• Operation manual
• Installation manual
Quantity
1 large 3 small
2 pcs.
Shape
M4 × 12L
Remote controller type
Model
Wired type
BRC1C51
BRC1A61
Wireless type
Heat pump type
BRC7E618
Cooling only
type
BRC7E619
01_EN_3P156215-10P.fm Page 3 Wednesday, April 2, 2008 11:47 AM