Si-93
Supplementary Explanation
Supplementary Explanation
61
1.1.7
Field Setting
(Example of setting operation)
Centralized control
group No. setting
(mode No.: 00)
1. Press
for more than 4 seconds.
2. Set mode No. to “00” using
or
.
3. Set centralized control group No. using
[
] or
[
].
4. Enter displayed group No. by pressing
.
5. Press
to return to normal operation mode.
Centralized control
group No. setting
(mode No.: 30)
For group control, the following step must be performed.
(*) Set unit No. using
.
Procedure for
entering individual
settings (mode No.:
44)
■
The setting is generally the same for all units in the same group control system. However, the setting of
selected units can be fixed by the following method.
< Example >
This setting method can be used when a group control system is connected with units having a different
airflow capacity from other units in the system.
1. Press
for more than 4 seconds.
2. Set mode No. to “44” using
or
.
3. Set unit No. using
.
4. Set airflow volume (ventilation mode) using
[
].
5. Set airflow direction (ventilation volume) using
[
].
6. Enter settings by pressing
.
(HL053)
Airflow volume
(air conditioner)
Mode No.
Unit No.
High
High
Low
Ventilation volume
at High
Ventilation volume fixed at Low
(HL054)
Airflow volume
(air conditioner)
Airflow direction
(air conditioner)
Unit No.
Ventilation mode
(heat reclaim ventilation unit)
Mode No.
Ventilation volume
(heat reclaim ventilation unit)
(HL055)
Содержание VAM 1000EJ
Страница 5: ...Si 93 iv Table of Contents ...
Страница 7: ...Introduction Si 93 vi 1 1 1 Cautions in Repair Warning ...
Страница 8: ...Si 93 Introduction vii ...
Страница 10: ...Si 93 General Constructions 1 Part 1 General Constructions 1 General Constructions 3 1 1 Explanation 3 ...
Страница 11: ...Si 93 2 General Constructions ...
Страница 15: ...Si 93 6 Operation ...
Страница 21: ...Si 93 12 Maintenance ...
Страница 27: ...Si 93 18 Control Functions ...
Страница 35: ...Si 93 26 Circuit Operations ...
Страница 39: ...Si 93 30 Troubleshooting ...
Страница 59: ...Troubleshooting Si 93 50 Troubleshooting ...
Страница 61: ...Si 93 52 Supplementary Explanation ...
Страница 72: ...Si 93 Appendix 63 Part 8 Appendix 1 Appendix 65 1 1 Wiring Diagram 65 ...
Страница 73: ...Si 93 64 Appendix ...
Страница 74: ...Si 93 Appendix Appendix 65 1 Appendix 1 1 Wiring Diagram VAM500EJVE VAM800EJVE VAM1000EJVE ...
Страница 75: ...Appendix Si 93 66 Appendix VAM2000EJVE ...
Страница 79: ...Si 93 iv Index ...
Страница 81: ...Si 93 vi Drawings Flow Charts When no indication is displayed on remote controller 45 Wiring Diagram 65 ...