background image

19

Advanced Setup

About Advanced Features & Operation

SET

NEXT

Press NEXT 

to advance

RESET 
FILTER

Press RESET 
FILTER

Press and hold the 
RESET FILTER button 
to reset the filter 
counter to 0 and 
remove the  
icon from the display.

Adjust the number of 
hours the blower will 
run before the  
icon appears on the 
display. 0 = off.

Slide the Program Switch to OFF or RUN to exit Advanced Setup.

CYCLES PER HOUR - The Cycles Per Hour setting (page 18) 

monitors the number of times per hour your HVAC unit may 

energize. For example, at a setting of 6 cycles per hour the HVAC 

unit will only be allowed to energize once every 10 minutes. The 

Cycles Per Hour limit may be temporarily overridden by pressing 

the WARMER or COOLER button.
TWO STAGE OPERATION - The 2nd stage of heat (auxiliary heat) 

is turned on when the room temperature is equal to or less 

than: the setpoint minus the 1st stage deadband (one degree, 

adjustable), minus the 2nd  

stage deadband (two  

degrees, non-adjustable).

 FILTER ICON - The 

 icon will appear after a set number 

of hours for fan run time (see above) has been achieved. This 

counter keeps track of the number of hours of fan run time 

whether the fan is energized in the heating or cooling modes, or 

in stand alone operation.

Actual hours of 

fan operation

Heat or Cool

Setpoint

Deadband

Deadband

db 1

db 2

(adj. 1˚-6˚ )

1st Stage

turn on

2nd Stage

turn on

Heating

(non-adj. 2˚)

Deadband

db 1

(adj. 1˚-6˚)

1st Stage

turn on

Cooling

Содержание TSTATD2152-2

Страница 1: ...Owner s Manual TSTATD2152 2 RESIDENTIAL for Residential Use DigitalThermostat Heat Pump 5 2 Day Programmable...

Страница 2: ...ormal Operation Manual Operation 6 Programmed Operation 7 Aux Heat 8 Clock Set 9 Time Period Programming Overview 10 Weekday Programming 11 Weekend Programming 14 Advanced Setup 18 Advanced Features 1...

Страница 3: ...e not immediately replaced Annual battery replacement is especially critical in locations subject to freezing temperatures The thermostat will be unable to turn on the heating system if the batteries...

Страница 4: ...R WARMER BUTTONS PROGRAM SWITCH RUN program Program OFF SET program SET HEAT BATTERIES COOL OFF PROGRAM RUN OFF SET RESET FILTER FAN NEXT HEAT AUX HEAT NORM EMRGC Y LOCKOUT AUTO ON On or Auto FAN SWIT...

Страница 5: ...e Mode Switch position When heat or cool is energized the Heat or Cool indicator will flash 3 Clock Display 4 Time period indicators These indicate the part of the program that is currently active if...

Страница 6: ...ected the fan will run continuously 3 Adjust the desired set temperature with the COOLER and WARMER buttons COOLER WARMER BUTTONS PROGRAM SWITCH RUN program Program OFF SET program SET HEAT BATTERIES...

Страница 7: ...fan will run continuously 4 The desired set temperature may be temporarily overridden The thermostat will revert to the programmed settings in the following time period COOLER WARMER BUTTONS PROGRAM...

Страница 8: ...all compressor functions and energizes only Aux Heat to satisfy the heat demand Normal Aux Heat is allowed to run if necessary along with the heat pump to satisfy the heat demand Lockout Aux Heat wil...

Страница 9: ...ogrammed from the factory to operate 1 or 2 Stage equipment without the need for further programming To optimize the installation of this thermostat follow the instructions in the Advanced Setup secti...

Страница 10: ...item in the time period programming screens will flash and can be modified with the COOLER WARMER buttons Continue the steps above until programming is complete Slide the Program Switch to RUN and th...

Страница 11: ...m Switch to SET page 9 Use these buttons to adjust the start time for the morning time period Use these buttons to adjust the cool setpoint for the morning time period Use these buttons to adjust the...

Страница 12: ...e cool setpoint for the day time period Use these buttons to adjust the heat setpoint for the day time period Use these buttons to adjust the start time for the evening time period Use these buttons t...

Страница 13: ...e heat setpoint for the evening time period Use these buttons to adjust the start time for the night time period Use these buttons to adjust the cool setpoint for the night time period Use these butto...

Страница 14: ...ime for the morning time period Use these buttons to adjust the cool setpoint for the morning time period Use these buttons to adjust the heat setpoint for the morning time period Use these buttons to...

Страница 15: ...setpoint for the day time period Use these buttons to adjust the heat setpoint for the day time period Use these buttons to adjust the start time for the evening time period Use these buttons to adju...

Страница 16: ...setpoint for the evening time period Use these buttons to adjust the start time for the night time period Use these buttons to adjust the cool setpoint for the night time period Use these buttons to...

Страница 17: ...ou have two options 1 Run the time period program by sliding the Program Switch to the RUN position OR 2 Do not run the time period program The thermostat will operate as a manual heat or cool thermos...

Страница 18: ...tem powered Use these buttons to adjust the deadband from 1 to 6 degrees Use these buttons to adjust the Cycles Per Hour from 2 to 6 d no limit zoning d1 d no compressor lockout page 19 Select backlig...

Страница 19: ...y 10 minutes The Cycles Per Hour limit may be temporarily overridden by pressing the WARMER or COOLER button TWO STAGE OPERATION The 2nd stage of heat auxiliary heat is turned on when the room tempera...

Страница 20: ...ch to SET When the clock is flashing press the NEXT button for 5 seconds Do not release the button until this screen appears When the Cycles Per Hour is flashing press and hold the NEXT button until t...

Страница 21: ...correctly perform the following procedure Enter advanced setup by sliding the Program Switch to SET When the clock is flashing press the NEXT button for 5 seconds Do not release the button until this...

Страница 22: ...g 1 To open the battery slot pull out on the battery door fig 1 and swing down fig 2 Remove the old batteries and replace with the new AA alkaline batteries fig 3 Push up on the battery door and snap...

Страница 23: ...52 2 and 2152 2 2200C 2 4271C 4272C 2111 2 4272 4273 Some states and provinces do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you DAIKIN SHALL...

Страница 24: ...ng Night Morning Day Evening Night Morning Day Evening Night Morning Day Evening Night MONDAY TUESDAY WEDNESDAY THURSDAY FRIDAY SATURDAY SUNDAY See page 10 Copy Mon to Tues No Yes Copy Tues to Wed No...

Отзывы: