T Sense Keypad Quick User & Installer Manual Rev 2.0
CLEAR ALARM MEMORY
COMMAND
INFORMATION
▪ Press & hold button [6] for 2 seconds
▪ Clear Zones, Strobe Light & Ext Comm. Error
DOOR CHIME
COMMAND
▪
Hold [7] for 2 sec + [Zone number 01 to 16] + [#]
REMARKS
-When door chime is activated, the keypad will sound each time the designed zone is triggered
SYSTEM SERVICE
COMMAND
INFORMATION
▪ Press & hold button [8] for 2 seconds
▪ Press the corresponding number to check the trouble
▪ Press [*] to Exit
Zone 1 (AC Power Loss)
Zone 2 (Low Battery)
Zone 3 (External Communication Failure)
Zone 4 (Telephone Line Loss)
Zone 5 (Tamper Zone)
REMARKS
-
Trouble LED (RED)
is
ON
when there is system trouble
-
Trouble LED
is
OFF
when there is no system trouble
BYPASS ZONE AND RESTORED
BYPASS
ZONE RESTORE
▪ Press & hold button [9] for 2 seconds
▪ Press [Zone Number]
▪ Press [#] to save and exit
Press [01] to [16] to select zone 1 to 16
Key in 2 digit
▪ Press & hold button [9] for 2 seconds
▪ Press [Zone Number]
▪ Press [#] to save and exit
Press [01] to [16] to select zone 1 to 16
Key in 2 digit
REMARKS
- Press
[01]
to
[16]
to select zone 1 to 16
again in this menu in order to have quick
BYPASS
and
ZONE RESTORE
-
In the normal mode, bypass zone will blinking to show that zone is already bypass.
-
Bypass zones are cleared after system is disarmed.
KEY LOCK
COMMAND
[COM] + [1] + [#]
REMARKS
-Key lock is design to avoid miss control by guest or kids.
- The “Key lock” icon on LCD will turn ON to indicate key lock is enabled and toggle based
PRECAUTION
-If user key in wrong password for 10x,the keypad will automatically lock by itself for 3 minutes
SERVICE
1 2 3 4 5
2