11
12
Titanium Apatite
Photocatalytic
Air-purifying Filter
Air filter
Catches dust
Wall-Mounted Type
6.0
kW class
FTKS60KAVMA
FTXS60KAVMA
5.0
kW class
FTKS50KAVMA
FTXS50KAVMA
7.1
kW class
FTKS71KAVMA
FTXS71KAVMA
Cooling only
Heat pump
2.5
kW class
FTKS25KVMA
FTXS25KVMA
2.0
kW class
FTKS20KVMA
FTXS20KVMA
3.5
kW class
FTKS35KVMA
FTXS35KVMA
Cooling only
Heat pump
Flat panel can be cleaned
with just a single pass of a
cloth across its smooth
surface.
Indoor unit lineup
Indoor unit lineup
Vertical and horizontal airflow is controlled
by Power-Airflow Dual Flaps and Wide-
Angle Louvers working in tandem, realising
even distribution of air.
Uses a Titanium Apatite Photocatalytic Air-Purifying
Filter. Titanium apatite is a photocatalytic material
with high adsorption power. It effectively adsorbs
and removes bacteria.
These filters are not medical devices. Benefits such as the
adsorption and decomposition of bacteria are only effective for
substances that are collected on and in direct contact with the
Titanium Apatite Photocatalytic Air-Purifying Filter.
Bacteria Removal Test
Testing method: dropping method
Result certificate: No. 012553-1 and 012553-2
Testing organisation: Japan Spinners Inspecting Foundation
Evenly distributed air
3-D airflow
Comfort airflow mode
Clean air
Easy cleaning
Wall-mounted type indoor units achieve quiet sound
level of 22 dB (A) during Indoor Unit Quiet Operation.
During cooling operation
Quiet operation
Intelligent eye
Intelligent Eye with its infrared sensor automatically
controls air conditioner operation according to human
movement in a room. When there is no movement, it
adjusts the temperature by
±
2˚C for energy efficiency.
Econo mode
Econo Mode is a function that reduces the maximum
running current and the maximum power
consumption of the outdoor unit to the rated values.
This mode is useful for preventing circuit breakers
from being overloaded by the use of multiple air conditioners
and other electrical devices. The function is easily activated
from the remote controller by pushing the ECONO button.
• This diagram is a representation for illustrative purposes only.
• Maximum capacity decreases during Econo Mode, requiring
more time to reach the set temperature.
Running current and power consumption
From start-up until set
temperature is reached
Maximum
Rated
Maximum during
normal operation
Time
Normal
operation
Econo
Mode
Maximum during
Econo Mode
Option
During cooling the Power-Airflow
Dual Flaps flatten out to deliver air
to the farthest corners of the room.
During heating the near-vertical flaps
direct air to the floor to quickly warm
the room.
*
* Heat pump only
3-D Airflow combines Vertical and Horizontal Auto-
Swing to circulate air to every part of a room for
uniform cooling/heating of even large spaces.
Comfort Airflow Mode prevents uncomfortable drafts
from blowing directly on to your body. With this
function, when you press the COMFORT button
during cooling operation, the flap moves upward to prevent
direct cold drafts. During heating operation, it also moves
downward to prevent direct drafts and deliver warm air to the
floor.
Cooling operation
Heating operation
When you are in the room.
When you go out.
A luminescent
material is
used for the
buttons on the
surface.
The LCD
panel with
backlight
Weekly Timer
operation button
The remote controller with a backlit liquid crystal
display and luminescent control buttons also
features a built-in Weekly Timer that can be
programmed to suit your lifestyle, with up to four actions per
day for each day of the week.
This controller not only allows you to programme on and off
times, but also the desired temperature during those times.
Furthermore, the ‘copy’ function enables any daily
programme to be replicated on any other day or days as
required.
Weekly timer
*
* Heat pump only
* Capacity may be affected.
FTXS25
FTXS20
FTXS35
42/26/
23
dB(A)
(H/L/
SL
)
38/25/
22
dB(A)
Option