Wiring Error Check Function
Trial Operation and Field Settings
258
Basic Knowledge
Refrigerant flows from Port A and on. The temperatures of the indoor heat exchanger
thermistors are detected one by one to check up the matching between the piping and wiring.
With this function on, freezing (crackling) noise may be heard from the indoor unit. This is not a
problem. (This is because the heat exchanger temperature is made to drop below 0°C in order
to increase the detection accuracy.)
The indoor fan is made to turn on or off at the same time.
Checking the
current setting
data on the
microcomputer
memory
Those data can be checked by looking at the service monitor LED indicators, when the wiring error
checking is over, during forced operation, at the stop of the system.
The LED indicators stop blinking when the forced operation is over.
LED1…Room A wiring, LED2…Room B wiring
1st blinking LED…Port A piping, 2nd blinking LED…Port B piping
The 1st blinking LED means the room that is connected with Port A. The 2nd blinking LED means
the one connected with Port B.
Example
Ex: Suppose the LED indicators are blinking as follows.
The above means that Port A is connected with Port B, and Port B with Room A (or self-corrected
this way.)
A 1 2 3 4
Green Red
Green Red
Green Red
A 1 2 3 4
A 1 2 3 4
(R8252)
L
E
D
L
E
D
L
E
D
A
B
Wiring
Piping
A
B
(R8253)
Wiring
Piping
Содержание SUPER MULTI NX CTXS07JVJU
Страница 1: ...Service Manual G Series J Series SiUS12 928_B Applied Models Inverter Multi Heat Pump...
Страница 9: ...SiUS12 928_B 1 List of Functions Part 1 List of Functions 1 Functions 2...
Страница 15: ...SiUS12 928_B 7 Specifications Part 2 Specifications 1 Indoor Unit 8 2 Outdoor Unit 13...
Страница 118: ...SiUS12 928_B CTXS L FTXS L Series Operation Manual 110 3 12 Quick Reference Quick Reference C 3P297290 1 C 3P297290 2...
Страница 140: ...SiUS12 928_B CDXS L FDXS L Series Operation Manual 132 5 10 Quick Reference Quick Reference C 3P297290 3...