background image

3 About the system

Operation manual

4

35A5V1B

R32 Split series

3P717028-1 – 2022.11

CAUTION

Do NOT operate the system when
using a room fumigation-type
insecticide. Chemicals could collect in
the unit, and endanger the health of
people who are hypersensitive to
chemicals.

WARNING

▪ The refrigerant inside the unit is

mildly flammable, but normally does
NOT leak. If the refrigerant leaks in
the room and comes in contact with
fire from a burner, a heater, or a
cooker, this may result in fire, or the
formation of a harmful gas.

▪ Turn OFF any combustible heating

devices, ventilate the room, and
contact the dealer where you
purchased the unit.

▪ Do NOT use the unit until a service

person confirms that the part from
which the refrigerant leaked has been
repaired.

WARNING

▪ Do NOT pierce or burn refrigerant

cycle parts.

▪ Do NOT use cleaning materials or

means to accelerate the defrosting
process other than those
recommended by the manufacturer.

▪ Be aware that the refrigerant inside

the system is odourless.

WARNING

The appliance shall be stored so as to
prevent mechanical damage and in a
well-ventilated room without
continuously operating ignition sources
(e.g. open flames, an operating gas
appliance, or an operating electric
heater). The room size shall be as
specified in the General safety
precaution.

DANGER: RISK OF
ELECTROCUTION

To clean the air conditioner or air filter,
be sure to stop operation and turn all
power supplies OFF. Otherwise, an
electrical shock and injury may result.

CAUTION

After a long use, check the unit stand
and fitting for damage. If damaged, the
unit may fall and result in injury.

WARNING

Be careful with ladders when working
in high places.

WARNING

Improper detergents or cleaning
procedure may cause damage on
plastic components or water leakage.
Splashed detergent on electric
components, such as motors, may
cause failure, smoke or ignition.

DANGER: RISK OF
ELECTROCUTION

Before cleaning, be sure to stop the
operation, turn the breaker OFF or pull
out the supply cord. Otherwise, an
electrical shock and injury may result.

WARNING

Stop operation and shut OFF the
power if anything unusual occurs
(burning smells etc.).

Leaving the unit running under such
circumstances may cause breakage,
electrical shock or fire. Contact your
dealer.

3

About the system

WARNING: FLAMMABLE MATERIAL

The refrigerant inside this unit is mildly flammable.

NOTICE

Do  NOT  use  the  system  for  other  purposes.  In  order  to
avoid  any  quality  deterioration,  do  NOT  use  the  unit  for
cooling  precision  instruments,  food,  plants,  animals,  or
works of art.

Содержание Siesta ATXD25A5V1B

Страница 1: ...Operation manual R32 Split series English Operation manual R32 Split series ATXD25A5V1B ATXD35A5V1B...

Страница 2: ...14 8 1 2 Symptom A blowing sound is heard 14 8 1 3 Symptom A ticking sound is heard 14 8 1 4 Symptom A whistling sound is heard 14 8 1 5 Symptom A clicking sound during operation or idle time is hear...

Страница 3: ...contains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries MUST be treated at a specialised treatment facility for reuse By ensuring waste batter...

Страница 4: ...ames an operating gas appliance or an operating electric heater The room size shall be as specified in the General safety precaution DANGER RISK OF ELECTROCUTION To clean the air conditioner or air fi...

Страница 5: ...ic Temperature setting 25 C Airflow rate Automatic 3 2 About the user interface Wireless remote control INFORMATION The indoor unit is delivered with the wireless remote control as the user interface...

Страница 6: ...g beep Operation stops 4 Before operation 4 1 To mount the wireless remote control holder c b a 2 a Wireless remote control b Screws field supply c Wireless remote control holder 1 Choose a place wher...

Страница 7: ...the temperature setpoint Cooling The system cools down a room to the temperature setpoint Fan The system only controls the airflow airflow rate and airflow direction The system does NOT control the t...

Страница 8: ...omatically sets the fixed airflow position upward in Cooling and downward in Heating operation mode Cooling operation mode Heating operation mode INFORMATION Powerful and Comfort airflow operation CAN...

Страница 9: ...ure setting 0 5 C up in cooling 2 0 C down in heating to prevent excessive cooling heating and ensure a comfortable sleeping temperature Use this feature if the unit is operating and you want to stop...

Страница 10: ...ss LAN is is off blinks in 0 5 second interval running and ready to connect to the home network via WPS button on the router is off blinks in 1 second interval connected to the home network via SSID K...

Страница 11: ...when using a room fumigation type insecticide Chemicals could collect in the unit and endanger the health of people who are hypersensitive to chemicals 7 Maintenance and service 7 1 Overview Maintena...

Страница 12: ...ssible consequence Discoloration and deformation Do NOT use water or air of 40 C or higher Possible consequence Discoloration and deformation Do NOT use polishing compounds Do NOT use a scrubbing brus...

Страница 13: ...anel at both sides and at the center until it clicks 7 8 To take following items into account before a long idle period 1 Set the mode to fan only by pressing button to dry the inside of the unit 2 Af...

Страница 14: ...inside a room becomes uneven It is necessary to clean the interior of the indoor unit Ask your dealer for details on cleaning the unit This operation requires a qualified service person When the air c...

Страница 15: ...voltage current sensor abnormality Outdoor temperature thermistor abnormality Discharge pipe thermistor abnormality Outdoor heat exchanger thermistor abnormality Electrical parts heat error Radiation...

Страница 16: ...TANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P717028 1 2022 11 Copyright 20...