4
Accessories
Indoor unit
A
Mounting plate
1
B
Air-purifying and deodorising
fi lter
1
C
Indoor unit fi xing screws
(M4 × 12L)
3
D
Wireless remote controller
1
E
Remote controller holder
1
F
Dry batteries AA.LR6 (alkaline)
2
Outdoor unit
G
Humidifying hose (8m)
1
H
Drain socket
1
J
Joint
1
K
Binding bands
3
L
Operation manual
1
M
Installation manual
1
•
The standard humidifying hose is 8m.
• The extension hose (option) is 2m (KPMH974A402).
• An humidifying hose of 10m (KPMH974A42) is also available as an option to replace the standard one (8m).
Choosing an Installation Site
Before choosing the installation site, obtain user approval.
1.
Indoor unit
•
The indoor unit should be sited in a place where:
1)
the restrictions on installation specifi ed in “
Indoor/Outdoor Unit
Installation Drawings
” on page 6 are met,
2) both air inlet and outlet are free of obstructions,
3) the unit is not in the path of direct sunlight,
4) the unit is away from the source of heat or steam,
5) there is no source of machine oil vapour (this may shorten indoor unit life),
6) cool/warm air is circulated throughout the room,
7)
the unit is away from electronic ignition type fl uorescent lamps (inverter or
rapid start type) as they may shorten the remote control range,
8) the unit is at least 1m away from any television or radio set (unit may cause
interference with the picture or sound),
9)
space allows for the moving range of the fl ap in operation above curtain
rails or other objects,
If (**) is 70mm or more, allow for 15mm of space from the indoor unit.
If it is less than 15mm, this can affect the opening and closing of the
shutter (bottom air inlet).
10) a height of 2.5m or more is allowed for installation,
11)
no laundry equipment is located nearby.
86
295
372*
370
179*
328*
150*
2500 or more
(**)
15
Including the mounting plate *
unit : mm
Shutter
(Bottom air inlet)
01_EN_3P338604-1E.indd 4
2/18/2019 14:09:12