7.4.

Setting the master remote controller

When the system is installed as shown in 

figure 8

 (RXYQ + RXYSQ

– the outdoor unit is connected to several indoor units) and 

figure 9

(REMQ – one BS unit is connected to several indoor units), it is
necessary to designate one of the remote controllers as the master
remote controller.

Only the master remote controller can select heating or cooling
and in case of REMQ units, automatic operation.

The displays of slave remote controllers show 

 (change-

over under centralized control) and slave remote controllers
automatically follow the operation mode directed by the master
remote controller.

However, it is possible to changeover to program dry with slave
remote controllers if the system is in cooling operation set by the
master remote controller.

How to designate the master remote controller

1

Press the operation mode selector button of the current master
remote controller for 4 seconds.

The display showing 

 (change-over under centralized

control) of all slave remote controllers connected to the same
outdoor unit or BS unit flash.

2

Press the operation mode selector button of the controller that
you wish to designate as the master remote controller. Then
designation is completed. This remote controller is designated
as the master remote controller and the display showing 
(change-over under centralized control) vanishes.

The displays of other remote controllers show 

 (change-

over under centralized control).

7.5.

Precautions for group control system or two 
remote controller control system

This system provides two other control systems beside individual
control (one remote controller controls one indoor unit) system.
Confirm the following if your unit is of the following control system
type.

Group control system
One remote controller controls up to 16 indoor units. All indoor
units are equally set.

Two remote controller control system
Two remote controllers control one indoor unit (in case of group
control system, one group of indoor units). The unit is
individually operated.

8.

E

NERGY

 

SAVING

 

AND

 

OPTIMUM

 

OPERATION

Observe the following precautions to ensure the system operates
properly.

Adjust the air outlet properly and avoid direct air flow to room
inhabitants.

Adjust the room temperature properly for a comfortable
environment. Avoid excessive heating or cooling.

Prevent direct sunlight from entering a room during cooling
operation by using curtains or blinds.

Ventilate often.
Extended use requires special attention to ventilation.

Keep doors and windows closed. If the doors and windows
remain open, air will flow out of your room causing a decrease in
the cooling or heating effect.

Be careful not to cool or heat too much. To save energy, keep
the temperature setting at a moderate level.

Never place objects near the air inlet or the air outlet of the unit.
It may cause deterioration in the effect or stop the operation.

Turn off the main power supply switch to the unit when the unit is
not used for longer periods of time. If the switch is on, it uses
electricity. Before restarting the unit, turn on the main power
supply switch 6 hours before operation to ensure smooth
running. (Refer to "Maintenance" in the indoor unit manual.)

When the display shows 

 (time to clean the air filter), ask a

qualified service person to clean the filters. (Refer to
"Maintenance" in the indoor unit manual.)

Keep the indoor unit and remote control at least 1 m away from
televisions, radios, stereos, and other similar equipment.
Failing to do so may cause static or distorted pictures.

Do not place items under the indoor unit which may be damaged
by water.
Condensation may form if the humidity is above 80% or if the
drain outlet gets blocked.

NOTE

Contact your dealer in case of changing the
combination or setting of group control and two remote
controller control systems.

Recommended temperature setting

For cooling

26~28°C

For heating

20~24°C

Содержание RXYQ16P7W1BA4 RXYQ18P7W1BA

Страница 1: ...Q8P7W1B RXYQ10P7W1B RXYQ12P7W1B RXYQ14P7W1BA RXYQ16P7W1BA RXYQ18P7W1BA RXYQ8P7W1B1 RXYQ10P7W1B1 RXYQ12P7W1B1 RXYQ14P7W1B1A RXYQ16P7W1B1A RXYQ18P7W1B1A REMQ8P7Y1B REMQ10P7Y1B REMQ12P7Y1B REMQ14P7Y1B RE...

Страница 2: ...4 1 2 3 1 1 4 2 2 3 1 1 4 3 9 2 3 1 3 1 2 1 1 5 3 5 2 4 6 UNIT NO 1 2 3 4 2 1 2 7 C D A B 8 RXYSQ RXYQ REYQ REMQ REMQ RXYSQ RXYQ REYQ REMQ REMQ 1 5 5 3 4 6 1 5 5 6 4 4 1 4 3 2 7 6 5 1 5 4 1 2 3 4 1 4...

Страница 3: ...spray such as hair spray lacquer or paint near the unit It may cause a fire Never touch the air outlet or the horizontal blades while the swing flap is in operation Fingers may become caught or the un...

Страница 4: ...result in injury Do not place a flower vase or anything containing water on the unit Water may enter the unit causing an electric shock or fire Do not place the controller exposed to direct sunlight T...

Страница 5: ...djust itself depending on the room temperature or the fan may stop immediately This is not a malfunction For systems without cool heat changeover remote control switch See figure 3 1 Press the operati...

Страница 6: ...ystem starts operation 4 Press the air flow direction adjust button Only for Double flow Multi flow Corner Ceiling suspended and Wall mounted Refer to 7 3 Adjusting the air flow direction on page 4 fo...

Страница 7: ...remote controller controls up to 16 indoor units All indoor units are equally set Two remote controller control system Two remote controllers control one indoor unit in case of group control system on...

Страница 8: ...is turned on The micro computer is getting ready to operate Wait 10 minutes Symptom 4 The fan strength does not correspond to the setting The fan strength does no change even if the fan strength adju...

Страница 9: ...unit Measure Stop the operation The operation switch does not work well Measure Turn off the power If the display the unit number and the operation lamp flash and the malfunction code appears See fig...

Страница 10: ...nditioning Recommended replacement cycle of wear parts Table 2 Replacement Cycle list Contact your dealer for details Moving and discarding the unit Contact your dealer for removing and reinstalling t...

Страница 11: ...NOTES NOTES...

Страница 12: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PW35770 1C...

Отзывы: