14
TROUBLE SHOOTING
TROUBLE SHOOTING
Trouble Shooting
These cases are not troubles.
The following cases are not air conditioner troubles but have some reasons. You may just continue using it.
Case
Explanation
Does not operate at all.
•
Check if the fuse has blown.
Set power switch to off.
•
Check if breaker has worked.
Turn the power on with the breaker switch in the
off position.
Do not turn the power on with the breaker switch in the trip position.
(Contact your dealer.)
•
When the power is interrupted.
Wait until the power is recovered, then operate the air conditioner again.
The air conditioner automatically resumes operation in about 3 minutes.
You should just wait for a while.
Operation does not start soon.
•
When ON/OFF button was pressed
soon after operation was stopped.
•
When the mode was reselected.
•
This is to protect the air conditioner.
You should wait for about 5 minutes.
(The microcomputer is preparing for operation. Wait for about 10 minutes.)
Hot air does not flow out soon after
the power supply is turned on.
•
The air conditioner is warming up. You should wait for about 1 minute. (The system
is designed to start discharging air only after it has reached a certain temperature.)
The heating operation stops suddenly
and a flowing sound is heard.
•
The system is taking away the frost on the outdoor unit.
You should wait for about 3 to 8 minutes. (Max. 10 minutes).
•
This sound indicates that the valve for the refrigerant bypass is in operation.
A “Zeen” sound is heard immediately
after the power supply is turned on.
•
The electronic expansion* valve inside an indoor unit starts working and
makes the noise. Its volume will reduce in about one minute.
* Electronic expansion valve … Controls the flow rate of the gas
(refrigerant) flowing inside the indoor unit.
A continuous low “Shah” sound is
heard when the system is in cooling
operation or at a stop.
•
When the drain pump (optional accessories) is in operation, this noise is
heard.
A “Pishi-pishi” squeaking sound is
heard when the system stops after
heating operation.
•
Expansion and contraction of plastic parts caused by temperature change
makes this noise.
A low “Sah”, “Choro-choro” sound is
heard while an indoor unit has stopped.
•
When the other indoor unit is in operation, this noise is heard. In order to prevent oil and
refrigerant from remaining in the system, a small amount of refrigerant is kept flowing.
A continuous low “Shuh” sound is
heard when the systems is in cooling
or defrost operation.
• This is the sound of refrigerant gas flowing through both indoor and
outdoor units.
A “Shuh” sound which is heard at the start
or immediately after the stop of operation
or which is heard at the start or immediately
after the stop of defrost operation.
• This is the noise of refrigerant caused by flow stop and flow change.
When the tone of operating noise changes.
•
This noise caused by the change of frequency.
A continuous “shuh” sound generated
during operation or immediately after
the operation is started or stopped.
•
This sound indicates that the valve for the refrigerant bypass is in operation.
The outdoor unit emits water or steam.
In heating mode
•
The frost on the outdoor unit melts into water or steam when the air
conditioner is in defrost operation.
In cooling or dry mode
•
Moisture in the air condenses into water on the cool surface of outdoor
unit piping and drips.
Mists come out of the indoor unit.
•
This happens when the air in the room is cooled into mist by the cold
airflow during cooling operation.
•
If the inside of an indoor unit is extremely contaminated, the temperature
distribution inside a room becomes uneven. It is necessary to clean the
inside of the indoor unit. Ask your Daikin dealer for details on cleaning the
indoor unit. This operation requires a qualified service person.
ON
Switch
Trip position
OFF
Breaker
01_EN_3P344160-13U.indd 14
06-Oct-20 2:42:06 PM
Содержание RXYMQ5BVM
Страница 2: ...00_CV_3P344160 13U indd 2 23 08 2020 14 09 18...
Страница 21: ...18 TROUBLE SHOOTING NOTES 01_EN_3P344160 13U indd 18 06 Oct 20 2 42 07 PM...
Страница 22: ...19 TROUBLE SHOOTING NOTES 01_EN_3P344160 13U indd 19 06 Oct 20 2 42 07 PM...
Страница 23: ...01_EN_3P344160 13U indd 20 06 Oct 20 2 42 07 PM...