Daikin RXS20K2V1B Скачать руководство пользователя страница 8

1

English

Safety Precautions

• The precautions described herein are classified as WARNING and CAUTION. They both contain important informa

-

tion regarding safety. Be sure to observe all precautions without fail.

• Meaning of WARNING and CAUTION notices

WARNING ........Failure to follow these instructions properly may result in personal injury or loss of life.

CAUTION .........Failure to observe these instructions properly may result in property damage or personal injury, which 

may be serious depending on the circumstances.

• The safety marks shown in this manual have the following meanings:

Be sure to follow the instructions.

Be sure to establish an earth connection.

Never attempt.

• After completing installation, conduct a trial operation to check for faults and explain to the customer how to operate 

the air conditioner and take care of it with the aid of the operation manual.

 WARNING

• Ask your dealer or qualified personnel to carry out installation work.

Do not attempt to install the air conditioner yourself. Improper installation may result in water leakage, electric shocks or fire.

• Install the air conditioner in accordance with the instructions in this installation manual.

Improper installation may result in water leakage, electric shocks or fire.

• Be sure to use only the specified accessories and parts for installation work.

Failure to use the specified parts may result in the unit falling, water leakage, electric shocks or fire.

• Install the air conditioner on a foundation strong enough to withstand the weight of the unit.

A foundation of insufficient strength may result in the equipment falling and causing injury.

• Electrical work must be performed in accordance with relevant local and national regulations and with instructions 

in this installation manual. Be sure to use a dedicated power supply circuit only.

Insufficiency of power circuit capacity and improper workmanship may result in electric shocks or fire.

• Use a cable of suitable length.

Do not use tapped wires or an extension lead, as this may cause overheating, electric shocks or fire.

• Make sure that all wiring is secured, the specified wires are used, and that there is no strain on the terminal connections or wires.

Improper connections or securing of wires may result in abnormal heat build-up or fire.

• When wiring the power supply and connecting the wiring between the indoor and outdoor units, position the wires 

so that the control box lid can be securely fastened.

Improper positioning of the control box lid may result in electric shocks, fire or over heating terminals.

• If refrigerant gas leaks during installation, ventilate the area immediately.

Toxic gas may be produced if the refrigerant comes into contact with fire.

• After completing installation, check for refrigerant gas leakage.

Toxic gas may be produced if the refrigerant gas leaks into the room and comes into contact with a source of fire, such as a fan heater, stove or cooker.

• When installing or relocating the air conditioner, be sure to bleed the refrigerant circuit to ensure it is free of air, 

and use only the specified refrigerant (R410A).

The presence of air or other foreign matter in the refrigerant circuit causes abnormal pressure rise, which may result in equipment damage and even injury.

• During installation, attach the refrigerant piping securely before running the compressor.

If the refrigerant pipes are not attached and the stop valve is open when the compressor is run, air will be sucked in, causing abnormal 
pressure in the refrigeration cycle, which may result in equipment damage and even injury.

• During pump-down, stop the compressor before removing the refrigerant piping.

If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed, 
causing abnormal pressure in the refrigeration cycle, which may result in equipment damage and even injury.

• Be sure to earth the air conditioner.

Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead. Imperfect earthing may result in electric shocks.

• Be sure to install an earth leakage breaker.

Failure to install an earth leakage breaker may result in electric shocks or fire.

 CAUTION

• Do not install the air conditioner at any place where there is a danger of flammable gas leakage.

In the event of a gas leakage, build-up of gas near the air conditioner may cause a fire to break out.

• While following the instructions in this installation manual, install drain piping to ensure proper drainage and 

insulate piping to prevent condensation.

Improper drain piping may result in indoor water leakage and property damage.

• Tighten the flare nut according to the specified method such as with a torque wrench.

If the flare nut is too tight, it may crack after prolonged use, causing refrigerant leakage.

• Make sure to provide for adequate measures in order to prevent that the outdoor unit be used as a shelter by small animals.

Small animals making contact with electrical parts can cause malfunctions, smoke or fire. Please instruct the customer to keep the area around the unit clean.

• The temperature of refrigerant circuit will be high, please keep the inter-unit wire away from copper pipes that are 

not thermally insulated.

01_EN_3P297037-2D.indd   1

11/1/2012   11:04:40 AM

Содержание RXS20K2V1B

Страница 1: ...ation S rie split R410A Montagehandleiding R410A Split systeem Manual de instalaci n Serie Split R410A Manuale dinstallazione Serie Multiambienti R410A R410A Manual de Instala o S rie split R410A R410...

Страница 2: ...e 2006 95 EC Electromagnetic Compatibility 2004 108 EC 3SB64564 12E Shinri Sada Manager Quality Control Department DAIKIN TCF 015 N4 09 2010 RXS20J2V1B RXS25J2V1B RXS35J2V1B RKS20J2V1B RKS25J2V1B RKS3...

Страница 3: ...ES LTD Low Voltage 2006 95 EC Electromagnetic Compatibility 2004 108 EC 3SB65451 3 RXS20K2V1B RXS25K2V1B Shinri Sada Manager Quality Control Department DAIKIN TCF 015 N20 09 2011 DEKRA Certification B...

Страница 4: ...meda Center Bldg 2 4 12 Nakazaki Nishi Kita ku Osaka 530 8323 Japan RXS20K2V1B RXS25K2V1B 3SB65451 4 Shinri Sada Manager Quality Control Department 3SB65451 4 fm Page 1 Thursday October 27 2011 4 49 P...

Страница 5: ...AIKIN TCF 015 P7 07 2012 DEKRA Certification B V NB0344 74736 KRQ EMC97 4957 3SB65451 14D Shinri Sada Manager Quality Control Department RXS20K3V1B RXS25K3V1B Machinery 2006 42 EC Electromagnetic Comp...

Страница 6: ...5 2 40 DAIKIN TCF 015 P9 09 2012 DEKRA Certification B V NB0344 74736 KRQ EMC97 4957 3SB65451 18F Shinri Sada Manager Quality Control Department RXS35K2V1B Machinery 2006 42 EC Electromagnetic Compati...

Страница 7: ...3SB65451 4 fm Page 2 Thursday October 27 2011 4 49 PM...

Страница 8: ...terminals If refrigerant gas leaks during installation ventilate the area immediately Toxic gas may be produced if the refrigerant comes into contact with fire After completing installation check for...

Страница 9: ...m television and radio sets This is to prevent interference to images and sounds Noises may be heard even if they are more than 3m away depending on radio wave conditions 8 In coastal areas or other p...

Страница 10: ...ove the screw on the stop valve cover Slide the lid downward to remove it How to attach the stop valve cover Insert the upper part of the stop valve cover into the outdoor unit to install Tighten the...

Страница 11: ...the unit securely by means of the foundation bolts Prepare 4 sets of M8 or M10 foundation bolts nuts and washers each which are available on the market It is best to screw in the foundation bolts unt...

Страница 12: ...lifetime The drying material may dissolve and damage the system Incomplete flaring may cause refrigerant gas leakage 4 Refrigerant piping work CAUTION Use the flare nut fixed to the main unit To preve...

Страница 13: ...52W mK 0 035 to 0 045kcal mh C Refrigerant gas pipe s surface temperature reaches 110 C max Choose heat insulation materials that will withstand this temperature 2 Be sure to insulate both the gas and...

Страница 14: ...nifold s low pressure valve Lo and completely close its high pressure valve Hi High pressure valve subsequently requires no operation 3 Do vacuum pumping and make sure that the compound pressure gauge...

Страница 15: ...nd manifold for charging The lled out label must be adhered in the proximity of the product charging port e g onto the inside of the stop valve cover NOTE National implementation of EU regulation on c...

Страница 16: ...peration press the switch SW1 1 2 3 The selective connector for standby electricity saving in use with standby electricity saving function turned off Push Screwdriver Power supply terminal block Force...

Страница 17: ...Earth leakage circuit breaker Earth Inter unit wire 4 core 1 5mm or more H05RN Firmly x the wires with the terminal screws Outdoor unit Indoor unit Power supply 50Hz 220 240V Firmly x the wires with t...

Страница 18: ...r in its standby mode If the system is not to be used for some time after installation shut off the circuit breaker to eliminate unnecessary power consumption If the circuit breaker trips to shut off...

Страница 19: ...Two dimensional bar code is a code for manufacturing 3P297037 2D M12B067A 1210 HT 00_CV_3P297037 2D indd 2 11 1 2012 11 01 11 AM...

Отзывы: