VRVII and VRVII-S system air conditioner

4PW16234-1C

Operation manual

 

4

 

For systems without cool/heat changeover remote control 

 

switch 

(See figure 3)

 

Press the operation mode selector button several times and

select the operation mode of your choice.

Press the on/off button.

The operation lamp lights up and the system starts operation.

 

For systems with cool/heat changeover remote control switch

Select operation mode with the cool/heat changeover remote

control switch as follows:

Press the on/off button.

The operation lamp lights up and the system starts operation.

Adjustment

For programming temperature, fan speed and air flow direction, refer
to the operation manual of the remote controller.

Stopping the system

Press the on/off button once again.

The operation lamp goes off and the system stops operation.

Explanation of heating operation

Defrost operation (heatpump and heatrecovery types only)

In heating operation, freezing of the outdoor unit coil increases.
Heating capability decreases and the system goes into defrost
operation.

The indoor unit fan stops and the remote controller displays

.

After maximum 10 minutes of defrost operation, the system
returns to heating operation again.

Hot start (heatpump and heatrecovery types only)

In order to prevent cold air from blowing out of an indoor unit at
the start of heating operation, the indoor fan is automatically
stopped. The display of the remote controller shows 

.

It may take some time before the fan starts. This is not a
malfunction.

6.2.

Program dry operation

The function of this program is to decrease the humidity in your
room with minimal temperature decrease (minimal room
cooling).

The micro computer automatically determines temperature and
fan speed (cannot be set by the remote controller).

The system does not go into operation if the room temperature
is low (<20°C).

For systems without cool/heat changeover remote control 
switch

Press the operation mode selector button several times and
select 

 (program dry operation).

Press the on/off button.
The operation lamp lights up and the system starts operation.

Press the air flow direction adjust button. (Only for Double-flow,

Multi-flow, Corner, Ceiling-suspended and Wall-mounted.)
Refer to 

"6.3. Adjusting the air flow direction" on page 5

 for details.

Stopping the system

Press the on/off button once again.

The operation lamp goes off and the system stops operation.

For systems with cool/heat changeover remote control switch 

(See figure 5)

Select cooling operation mode with the cool/heat changeover
remote control switch.

Press the operation mode selector button several times and
select 

 (program dry operation).

Press the on/off button.
The operation lamp lights up and the system starts operation.

Press the air flow direction adjust button. (Only for Double-flow,

Multi-flow, Corner, Ceiling-suspended and Wall-mounted.)
Refer to 

"6.3. Adjusting the air flow direction" on page 5

 for details.

Stopping the system

Press the on/off button once again.

The operation lamp goes off and the system stops operation.

Cooling operation

Heating operation

Automatic operation

Fan only operation

NOTE

Automatic operation (REYQ only)

In this operation mode, cool/heat changeover is
automatically conducted.

 

Cooling operation (

figure 4.1

)

 

Heating operation (

figure 4.2

)

Fan only operation (

figure 4.3

)

NOTE

Do not turn off power immediately after the unit stops,
but wait for at least 5 minutes.

1

2

1

2

3

NOTE

The heating capacity drops when the outside
temperature falls. If this happens, use another
heating device together with the unit. (When using
together with appliances that produce open fire,
ventilate the room constantly.)
Do not place appliances that produce open fire in
places exposed to the air flow from the unit or
under the unit.

It takes some time to heat up the room from the
time the unit is started since the unit uses a hot-
air circulating system to heat the entire room.

If the hot air rises to the ceiling, leaving the area
above the floor cold, we recommend that you use
the circulator (the indoor fan for circulating air).
Contact your dealer for details.

NOTE

Do not turn off power immediately after the unit stops,
but wait for at least 5 minutes.

NOTE

Do not turn off power immediately after the unit stops,
but wait for at least 5 minutes.

1

2

3

4

1

2

3

4

5

Содержание RXQ5M7W1B

Страница 1: ...9W1B RXYQ10M9W1B RXYQ12M9W1B RXYQ14M9W1B RXYQ16M9W1B RXYQ18M9W1B RXYQ20M9W1B RXYQ22M9W1B RXYQ24M9W1B RXYQ26M9W1B RXYQ28M9W1B RXYQ30M9W1B RXYQ32M9W1B RXYQ34M9W1B RXYQ36M9W1B RXYQ38M9W1B RXYQ40M9W1B RXY...

Страница 2: ...2 3 1 1 4 3 2 3 1 3 1 2 1 1 5 3 5 2 4 6 UNIT NO 1 2 3 4 2 1 2 7 Ceiling Suspended Wall Mounted Double flow Multi flow Corner 8 RXYSQ RXYQ 1 1 4 4 3 2 6 7 5 5 REYQ 1 RXYSQ RXYQ 1 5 5 4 3 2 4 7 1 5 5 4...

Страница 3: ...y for future reference WARNING Improper handling can lead to such serious consequences as death severe injury or damage to the equipment NOTE These instructions will ensure proper use of the equipment...

Страница 4: ...door unit It may cause incomplete combustion or deformation of the unit due to the heat Do not allow a child to mount on the outdoor unit or avoid placing any object on it Falling or tumbling may resu...

Страница 5: ...rt automatically after the power turns back on again 6 1 Cooling heating fan only and automatic operation See figure 3 and figure 4 1 Changeover cannot be made with a remote controller whose display s...

Страница 6: ...dry operation Press the on off button The operation lamp lights up and the system starts operation Press the air flow direction adjust button Only for Double flow Multi flow Corner Ceiling suspended a...

Страница 7: ...ller control system Two remote controllers control one indoor unit in case of group control system one group of indoor units The unit is individually operated 7 ENERGY SAVING AND OPTIMUM OPERATION Obs...

Страница 8: ...he power is turned on The micro computer is getting ready to operate Wait 10 minutes Symptom 4 The fan strength does not correspond to the setting The fan strength does no change even if the fan stren...

Страница 9: ...e power If the display the unit number and the operation lamp flash and the malfunction code appears See figure 6 Measure Notify your dealer and report the malfunction code If the system does not prop...

Страница 10: ...ong sites with 24 hour air conditioning Recommended replacement cycle of wear parts Table 2 Replacement Cycle list Contact your dealer for details Moving and discarding the unit Contact your dealer fo...

Страница 11: ...NOTES NOTES...

Страница 12: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PWEN16234 1C...

Отзывы: