Compressor
Si001655E
22
Removal Procedure
2
3
Remove the protection
bushing.
Disconnect the
compressor lead wires
and the overload
protector.
4
5
6
7
8
Remove the putty.
Heat up the brazed part
of the discharge side
pipe and disconnect it.
Heat up the brazed part
of the suction side pipe
and disconnect it.
Remove the 3 nuts of
the compressor.
Lift up the compressor
and remove it.
Step
Procedure
Points
Protection
bushing
U (red)
W (blue)
Overload protector
V (yellow)
(R20423)
Compressor
Putty
Brazed part of the
discharge side pipe
Brazed part of the
suction side pipe
Nut
(R20425)