6 Disposal
Installation manual
14
RXF50+60A2V1B
R32 split series
3P512025-3 – 2017.11
c
b
a
d
d
e
a
Gas stop valve
b
Closing direction
c
Hexagonal wrench
d
Valve lid
e
Liquid stop valve
6.3
To start and stop forced cooling
There are 2 methods to perform forced cooling operation:
▪ using the indoor unit ON/OFF switch (if present on the indoor
unit).
▪ using the indoor unit user interface.
Method 1: Using the indoor unit ON/OFF switch
1
Press the ON/OFF switch for at least 5 seconds.
Result:
Operation will start.
Result:
Forced cooling stops automatically after 15 minutes.
2
To stop operation, press the ON/OFF switch.
Method 2: Using the indoor unit user interface
3
Set the operation mode to
cooling
.
For the procedure, refer to the chapter "To perform a test run" in the
installation manual of the indoor unit.