Electrical Box
Si001419E
8
Removal Procedure
4
Disconnect the
connector [S80] and
pull out the clamp (Hole
No.5).
[S80]: four way valve coil
When reassembling,
connect the connectors in
the following order. Be sure
to insert the wiring clamps of
lead wires into the
appropriate holes.
(1) [S90]: Hole No.15,
14, 13, 7, 3
(2) [S40]: Hole No.16, 2
(3) [S20]: Hole No.10
(4) [S80]: Hole No.5
5
Disconnect the
connector [S20] and
pull out the clamp (Hole
No.10).
Step
Procedure
Points
[S80]
Clamp
(R20922)
14
15
16
13
Hole No. for wiring clamps
1
3
5
7
9
11
2
4
6
8
10 12
(R20993)
[S20]
Clamp
(R20923)
[S20]: electronic expansion
valve coil