Electronic Expansion Valve / Four Way Valve
Si001555EC
20
Removal Procedure
2
Remove the screw and
remove the four way
valve coil.
The cooling only models
have no four way valve coil.
3
Remove the terminal
cover.
4
5
Remove the protection
bushing.
Disconnect the
compressor lead wires
and the overload
protector.
Step
Procedure
Points
Four way valve coil
(R21991)
Terminal cover
(R21992)
Protection bushing
Overload
protector
V (yellow)
W (blue)
U (red)
(R21993)