![Daikin RX-GV Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/daikin/rx-gv/rx-gv_technical-data-manual_2459898006.webp)
• Outdoor Units • R-410A • RX-JV/GV
• Split Sky Air • Outdoor Units
4
2
Specifications
Power Input
Cooling
Max.
kW
2.08
2.40
3.20
Min.
kW
0.44
0.57
Nom.
kW
1.55
1.99
2.35
Heating
Max.
kW
2.53
2.81
3.82
Min.
kW
0.40
0.52
Nom.
kW
1.60
2.04
2.55
For combination indoor
units + outdoor units
EER
Nominal
3.23
3.02
COP
Nominal
3.63
3.43
3.22
Energy Label
Cooling
A
B
B
Heating
A
B
C
Annual energy consumption
kWh
3000
3350
4250
2-2 Technical Specifications
RX20JV1B
RX25JV1B
RX35JV1B
Casing
Colour
Ivory White
Dimensions
Unit
Height
mm
550
Width
mm
658
Depth
mm
275
Packing
Height
mm
616
Width
mm
788
Depth
mm
359
Weight
Unit
kg
28
28
30
Packed Unit
kg
31
31
34
Heat Exchanger
Dimensions
Length
mm
670
670
647
Nr of Rows
1
1
2
Fin Pitch
mm
1.4
1.4
1.4
Nr of Stages
24
24
24
Tube type
Hi-Xa(7)
Fin
Type
Waffle fin
Fan
Type
Propeller
Quantity
1
1
1
Air Flow Rate
Cooling (High)
m³/min
29.2
29.2
27.6
Heating (High)
m³/min
26.2
26.2
24.5
Cooling (High)
cfm
1,030
1,030
975
Heating (High)
cfm
927
927
865
Motor
Quantity
1
1
1
Model
KFD-280-33-8A
Motor
Speed (nominal)
Cooling (Low)
rpm
720
720
720
Cooling (High)
rpm
860
860
860
Heating (Low)
rpm
350
350
350
Heating (High)
rpm
860
860
860
Fan
Motor
Output
W
33
33
33
Motor
Model
KFD-280-33-8A
Type
Propeller
Compressor
Quantity
1
1
1
Motor
Model
1YC23AEXDA
Type
Hermetically sealed swing compressor
Motor Output
W
750
750
750
Operation Range
Cooling
Min
°CDB
10
10
10
Max
°CDB
46
46
46
Heating
Min
°CWB
-15
-15
-15
Max
°CWB
20
20
20
Sound Level
(nominal)
Cooling
Sound Power
dBA
60
60
62
Sound Pressure
(High)
dBA
46
46
48
Heating
Sound Pressure
(High)
dBA
47
47
48
Refrigerant
Type
R-410A
Charge
kg
0.74
0.74
1.0
2-1 Nominal Capacity and Nominal Input
RX50G2V1B
RX60G2V1B
RX71GV1B
RX-JV-GV_EN.pdf 6