3
Refrigerant Recycle Equipment
◆ Do not have the electric cord connected to other electrical devices or
with other cords.
It may cause fire.
◆ Do not pull on the electric power cord to remove from the outlet.
It may cause fire or injury.
◆ The power source should be AC220-240V 10A or use a generator with
the capacity of 3KVA or more.
If the capacity of the generator is not large enough, it may lead to overheating, smoking
or fire. See the specification label or this manual for the detailed specifications.
◆ Do not set up the unit in a location where gasoline, thinner, or
flammable gas exists.
The recycle unit sparks at the start-up time and may ignite gasoline and thinner.
If leaked gasoline or flammable gas accumulates at near the unit, it may cause explosion
and fire.
◆ Always turn off the switch and pull out the power cord during
inspection and maintenance.
The unit may suddenly start and cause accident.
◆ Do not disassemble. The unit should only be repaired by an authorized
repair person.
◆ Do not operate the unit with the cover removed.
It may cause injury or damage.
◆
Various safety devices are built into this unit. Always carry out pre-
start inspection according to page 18 "INSPECTION BEFORE WORK"
before using.
If any abnormality is found in the unit, please stop using it immediately and contact your
dealer or our sales representative.
WARNING
CAUTION
◆ Transport carefully.
The unit may get damaged but this may also cause injury.
◆ When moving the unit, push it with the handle. Do not pull the unit.
◆ Install Filter at Suction Port.
Otherwise the compressor may be damaged.
◆ Any extension cord should be a three-core cabtyrecable with at least
2.0mm
2
diameter if 20m or less or 3.5mm diameter if 20 to 30m long.
An unsuitable extension cord (too thin or too long) may lead to failure or fire, or
electrical components may be damaged.
If the cord used is a two-core cord without a ground wire, it may cause an electric
shock.
◆ Do not recycle refrigerant which contains sealant.
Sealant may clog the valves or the check valves.
WARNING FOR SAFETY