Parameter settings
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
Operating instructions
49
6.13
Parameter levels of the EHS157068 mixer module
The parameter levels, parameter meanings, setting ranges and
connected functions are basically described in the same way as
in the previous sections.
An unlimited scope of available parameters exists at the indi-
vidual levels.
Only the corresponding sections are referred to below. Signif-
icant differences are explained in more detail.
Rotary switch setting: Info
See chap. 6.10.
When setting the assigned control unit to "Mix Valve #0", the dis-
played values refer to the assigned heating circuit and the com-
ponents connected to the EHS157068. (pump, mixer valve, …).
When setting the assigned control unit to "Living Room", the [T-
Room adj] parameter is available. The room target temperature
can be changed in the range -5 K to +5 K with the rotary button.
This function is not available if the control unit is used as a remote
control in terminal function.
Rotary switch setting: Operating Mode
See chap. 6.4.
Rotary switch setting: Set Temp Day
See chap. 6.5.
Rotary switch setting: Set Temp Night
See chap. 6.6.
Rotary switch setting: DHW Set Temp
No function.
Rotary switch setting: DHW Reheating
No function.
Rotary switch setting: Time Program
See chap. 6.8.
Rotary switch setting: Configuration
Rotary switch setting: Remote Param
See chap. 6.9.
6.13.1
Rotary switch setting: Configuration
, "Setup" level
Sub
-
le
vel
Parameter
Description
Access
Setting range
Min / Max
Factory
setting
Incre-
ment
BE
HF
LCD Contrast
Display contrast
E
E
1-10
4
1
LCD Brightness
Brightness of the display
E
E
0-100 %
50 %
10 %
LCD Illum Time
Lighting duration of the display
E
E
5-120 s
30 s
1 s
Language
National language of the display texts on the control unit
E
E
German
English
French
Dutch
Italian
Spanish
Portuguese
German
1
Date
Current date in day/month/year format. The current day of the week is calculated auto-
matically from the date.
E
E
Time
Time in hours/minutes format.
E
E
Keylock Function
Release of the key lock function:
Off: Key lock cannot be activated.
On: Key lock can be activated with the rotary button (see chap. 3.1).
E
E
Off
On
Off
-
Access Rights
Access code entry. Setting digit-by-digit like a combination lock (see chap. 3.6.1).
E
E
0 - 9
0000
1
RoCon U1 assign
Only for connected room control
:
Function of the EHS157034 room control in the data bus system:
Living Room: Room thermostat for the Daikin heat generator
Mix Valve: Mixer circuit operating unit (as mixer circuit extension or as a free-standing
mixer circuit control unit)
Solar: Not applicable
In addition to the above-mentioned functions, the room controller can basically be used
as a remote control unit for the Daikin heat generator and the entire RoCon system (with
activated terminal function) (see chap. 4.4.2).
N
E
Living Room
Mix Valve
Solar
Living Room
-
Master-RoCon
Setting of the caretaker function
Off: Deactivated
On: Function active
For every EHS157034 room control whose intended use is set to "Living Room" and
that is assigned to a heat generator ([Boiler Assignment] parameter >0), the caretaker
function is activated (see chap. 4.4.5). Several room controls with active caretaker func-
tion are possible in the system.
In "Operating Mode" rotary switch setting, the operating mode setting of the heat gener-
ator is set (can deviate from the heating circuit assignment of the control unit). As a re-
sult, the functions for hot water generation can also be remotely operated from the room
controller.
N
E
Off
On
Off
-
PWM Config
Min Perform Pump
Lower limit for modulation of the pump power
N
E
0 - 100 %
50 %
1 %
Max Perform Pump
Upper limit for modulation of the pump power
N
E
0 - 100 %
100 %
1 %