Installation manual
1
RMXS112~160D7V3B
Super Multi Plus System air conditioner
4PW19516-1B
C
ONTENTS
Page
1. Safety considerations ................................................................ 1
2. Introduction................................................................................ 2
2.1. System layout .................................................................................. 2
2.2. Combination .................................................................................... 3
2.3. Standard supplied accessories ....................................................... 3
2.4. Optional accessories ....................................................................... 3
2.5. Technical and electrical specifications............................................. 3
3. Before installation ...................................................................... 3
4. Selecting installation site ........................................................... 3
5. Precautions on installation......................................................... 4
6. Installation servicing space ....................................................... 5
7. Refrigerant pipe size and allowable pipe length ........................ 6
7.1. Selection of piping material ............................................................. 6
8. Precautions on refrigerant piping............................................... 6
9. Refrigerant piping ...................................................................... 7
9.1. Preventing foreign objects from entering ......................................... 7
9.2. Cautions for handling stop valve...................................................... 7
9.3. How to use the shut-off valve .......................................................... 8
9.4. Cautions for handling the valve cover.............................................. 8
9.5. Cautions for handling service port................................................... 8
9.6. Precautions when connecting field piping and regarding insulation ..8
9.7. Example of connection .................................................................... 9
9.8. Leak test and vacuum drying ........................................................ 10
9.9. Additional refrigerant charge ......................................................... 10
10. Electrical wiring work ............................................................... 11
10.1. Internal wiring – Parts table ........................................................... 11
10.2. Precautions on electrical wiring work ............................................ 12
10.3. Connection example of total system wiring ................................... 12
10.4. Connecting power wire and transmission wires ............................ 12
10.5. Power circuit and cable requirements............................................ 13
11. Before operation ...................................................................... 14
11.1. Service precautions....................................................................... 14
11.2. Checks before initial start-up ......................................................... 14
11.3. Field setting ................................................................................... 15
11.4. Test operation ................................................................................ 16
11.5. Temperature adjustment operation confirmation ........................... 17
13. Caution for refrigerant leaks .................................................... 18
14. Disposal requirements............................................................. 18
1. S
AFETY
CONSIDERATIONS
The precautions listed here are divided into the following two types.
Both cover very important topics, so be sure to follow them carefully.
RMXS112D7V3B
RMXS140D7V3B
RMXS160D7V3B
System air conditioner
Installation manual
Super Multi Plus
READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLATION. KEEP THIS MANUAL IN A HANDY
PLACE FOR FUTURE REFERENCE.
IMPROPER INSTALLATION OR ATTACHMENT OF
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY
TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE
SPECIFICALLY DESIGNED FOR USE WITH THE
EQUIPMENT AND HAVE THEM INSTALLED BY A
PROFESSIONAL.
DAIKIN EQUIPMENT IS DESIGNED FOR COMFORT
APPLICATIONS. FOR USE IN OTHER APPLICATIONS,
PLEASE CONTACT YOUR LOCAL DAIKIN DEALER.
IF UNSURE OF INSTALLATION PROCEDURES OR USE,
ALWAYS CONTACT YOUR DEALER FOR ADVICE AND
INFORMATION.
WARNING
If the warning is not observed, it may cause serious casualties.
CAUTION
If the caution is not observed, it may cause injury or damage to the
equipment.
WARNING
■
Ask your dealer or qualified personnel to carry out
installation work. Do not install the machine by
yourself.
Improper installation may result in water leakage,
electric shocks or fire.
■
Perform installation work in accordance with this
installation manual.
Improper installation may lead to water leakage,
electric shocks or fire.
■
When a unit is installed in a small room, it is necessary
to take measures so that the leaked refrigerant amount
does not exceed the limit even if it leaks. As for the
measures to prevent the leak from not exceeding the
limit, please consult with your distributor.
If the leaked amount exceeds the limit, it may cause
an oxygen deficiency accident.
■
Be sure to use only the specified accessories and
parts for installation work.
Failure to use the specified parts may result in water
leakage, electric shocks, fire, or the unit falling.
■
Install the air conditioner on a foundation that can
withstand its weight.
Insufficient strength may result in the fall of equipment
and causing injury.