Outdoor Fan Motor Abnormality
Error Code
E7
Method of Error
Detection
The error is determined according to the fan speed detected by Hall IC when the fan motor runs.
Error Decision
Conditions
When the fan runs with speed less than a specified one for 6 seconds or more when the fan
motor running conditions are met
When the error is generated 4 times, the system shuts down.
Clearing condition: Operate for 5 minutes (normal)
Supposed
Causes
Defective fan motor
Disconnection of connector
Fan does not rotate due to tangled foreign matters
Troubleshooting
Check No.32
Refer to P.222
Note:
Refer to page 139 for detail about monitor mode.
Is
the connector
of the fan motor
disconnected?
Is there any
obstacle around the
outdoor fan?
Are the
resistances between
pins above
judgment?
Can the
outdoor fan be
turned smoothly by hand
after disconnecting the
connector?
Connect the connector.
Remove the obstacle.
Replace outdoor unit PCB.
(R15332)
NO
NO
YES
YES
YES
Replace the fan motor.
NO
Replace the fan motor.
NO
YES
Check No.32
Check the resistance of fan
motor connector.
Turn off the power and wait for 10 minutes.
Outdoor unit has 2 fan motors.
Identify the defective one (M1F or M2F) in
monitor mode. (See note.)
Caution
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Содержание RMXS-L Series
Страница 10: ...Safety Considerations Safety Considerations ix...
Страница 11: ...SiUS181305E 1 List of Functions Part 1 List of Functions 1 Functions 2 1 1 Outdoor Unit 2 1 2 Indoor Unit 3...
Страница 129: ...SiUS181305E Field Settings Test Operation and Field Settings 120...
Страница 144: ...FFQ09 12 15 18LVJU SiUS181305E 135 Remote Controller...
Страница 249: ...SiUS181305E Removal Procedure Booklet No Appendix 240...