Si001170
Removal of Electrical Box / PCB
Removal Procedure
7
3. Removal of Electrical Box / PCB
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1. Remove the right side
panel.
Preparation
Remove the panels
according to the “Removal
of Outer Panels”.
1
Unhook the outdoor
temperature thermistor.
2
Remove the 2 screws
and remove the
terminal cover.
3
Remove the screw and
remove the stop valve
cover.
4
Remove the screws
and disconnect the
connecting wires.
5
Remove the 3 screws
and remove the wire
clamp.
(R14867)
Outdoor temperature thermistor
Stop valve
cover
Terminal cover
(R14868)
(R14869)
(R14870)
Wire clamp