![Daikin RKN25KEVM Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/daikin/rkn25kevm/rkn25kevm_removal-procedure_2459846021.webp)
Si001170
Removal of Compressor
Removal Procedure
19
6. Removal of Compressor
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1. Remove the peripheries.
1
Remove the terminal
cover.
2
Remove the protection
bushing.
3
Disconnect the
terminals and overload
protector.
Terminal cover
(R14904)
Protection bushing
(R14905)
(R14906)
W
(blue)
V (yellow)
U
(red)
Содержание RKN25KEVM
Страница 1: ...REMOVAL PROCEDURE S E R V I C E M A N U A L Outdoor Unit Inverter Pair Type 2 5 3 5 kW Class Si001170...
Страница 2: ...Service Manual Removal Procedure Outdoor Unit Applicable Models zCooling Only RKN25KEVM RKN35KEVM...