manualshive.com logo in svg
background image

REMOVAL

PROCEDURE

S E R V I C E   M A N U A L

18000 Btu/h Class

Outdoor Unit

Inverter

Pair Type

Si001556E

Содержание RKN18NMVJU

Страница 1: ...REMOVAL PROCEDURE S E R V I C E M A N U A L 18000 Btu h Class Outdoor Unit Inverter Pair Type Si001556E...

Страница 2: ...Service Manual Removal Procedure Outdoor Unit zCooling Only RKN18NMVJU...

Страница 3: ...moval Procedure 1 Table of Contents 1 Outer Panels 2 2 Outdoor Fan Fan Motor 4 3 Electrical Box 7 4 PCB 10 5 Thermistor ASSY Partition Plate 12 6 Sound Blankets 16 7 Electronic Expansion Valve Coil Co...

Страница 4: ...turning off all power supplies before disassembling work Step Procedure Points 1 Remove the 6 screws and remove the top panel 2 Remove the 8 screws of the front panel 3 Slide the fan motor fixing fra...

Страница 5: ...n the 2 hooks on the right side Remove the front panel 6 Remove the 4 screws of the discharge grille 7 Unfasten the 2 hooks and remove the discharge grille Step Procedure Points Hook Front panel R2187...

Страница 6: ...rning off all power supplies before disassembling work Step Procedure Points 1 Remove the drip proof cover 2 3 Disconnect the connector S71 Pull out the bottom clamp of the fan motor lead wire S71 fan...

Страница 7: ...embling When reassembling put the fan motor lead wire through the back of the fan motor so as not to be entangled with the outdoor fan 6 Remove the 2 screws and remove the fan motor fixing frame When...

Страница 8: ...6E 6 Removal Procedure 7 Unfasten the 3 hooks on the fan motor fixing frame and release the fan motor lead wire 8 Remove the 4 screws and remove the fan motor Step Procedure Points Fan motor lead wire...

Страница 9: ...terminal cover 2 3 Open the terminal cover and pull down to unfasten the 2 hooks Remove the terminal cover 4 5 6 Remove the 7 screws on the terminal board and disconnect the connecting wire and power...

Страница 10: ...te to the right side panel 8 Remove the 2 screws 9 Disconnect the connector S20 S20 electronic expansion valve coil 10 Disconnect the 2 connectors from the reactor When reassembling you can reconnect...

Страница 11: ...40 overload protector 12 Disconnect the connector S30 S30 compressor motor 13 Disconnect the connector S90 and pull out the clamp S90 thermistors 14 Remove the screw and remove the electrical box Step...

Страница 12: ...work Step Procedure Points 1 Remove the screw of the terminal board 2 Remove the earth ground screw and pull out the clamp from the mounting plate for terminal board 3 Remove the earth ground screw fr...

Страница 13: ...ocedure 11 4 5 Remove the 3 screws of the PCB Unfasten the 2 spacers and the 2 hooks to remove the PCB A long screwdriver is necessary for removing these screws Step Procedure Points Spacer Spacer Hoo...

Страница 14: ...upplies before disassembling work Step Procedure Points 1 Remove the screw of the stop valve cover 2 Slide the stop valve cover downward and remove it When reassembling make sure to fit the 3 hooks 3...

Страница 15: ...the right side panel When reassembling make sure to fit all the hooks 6 Pull out the outdoor heat exchanger thermistor and cut the clamp Be careful not to lose the clip for the thermistor Step Procedu...

Страница 16: ...t to lose the fixture for the thermistor 8 Remove the thermistor ASSY 9 Pull out the clamp 10 11 12 Remove the 2 screws of the reactor Slide the reactor upward to unfasten the 2 hooks Remove the react...

Страница 17: ...SY Partition Plate Removal Procedure 15 13 Remove the 2 screws and remove the partition plate When reassembling fit the lower hook into the bottom frame Step Procedure Points Partition plate R21910 Ho...

Страница 18: ...er supplies before disassembling work Step Procedure Points 1 Remove the sound blanket top Since the piping ports on the sound blanket are torn easily remove the blanket carefully 2 Open and pull up t...

Страница 19: ...llect all the refrigerant gas Restore the piping by non oxidation brazing Note Before working make sure that the refrigerant gas is empty in the circuit Be sure to apply nitrogen replacement when heat...

Страница 20: ...r 5 6 7 8 Heat up the brazed part of the discharge side pipe and disconnect it Heat up the brazed part of the suction side pipe and disconnect it Remove the 3 nuts Lift up the compressor and remove it...

Страница 21: ...Revision History Month Year Version Revised contents 07 2015 Si001556E First edition...

Страница 22: ...ories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of parts and acc...

Отзывы: