![Daikin RKJ09NV1S Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/daikin/rkj09nv1s/rkj09nv1s_service-manual_4201044018.webp)
Four Way Valve
Si001273EC
16
Removal Procedure
2
Remove the terminal
cover.
3
Disconnect the lead
wires of the compressor
and the overload
protector.
4
Remove the screw and
remove the four way
valve coil.
Step
Procedure
Points
(R7234)
Terminal cover
V
W
U
(R20182)
Red (U)
Yellow (V)
Blue (W)
Overload
protector
(R20193)
Four way valve coil