Si011281E

Electrical Components

Removal Procedure

7

2. Remove the electrical 

component ASSY.

„

Compressor motor capacitor 
(C1)

1

Pull out all the 3 
terminals from the 
compressor motor 
capacitor (C1).

2

Pull out the terminal 
(white: 3_lower) from 
the terminal board 
(X1M).
 

3

Remove the screw and 
remove the electrical 
component ASSY.

Step

Procedure

Points

Compressor motor capacitor

Terminal board

(R18997)

white, 3 lower

(R19151)

(R19011)

to compressor (S): red

to compressor (R): blue

to terminal board 
(2_upper): blue

Electrical component ASSY

(R18999)

(R19000)

Compressor motor capacitor

Terminal 

board

Fan motor capacitor

Содержание RE50NRV16

Страница 1: ...5 0 6 0 kW Class REMOVAL PROCEDURE S E R V I C E M A N U A L Outdoor Unit Non Inverter Pair Type Si011281E...

Страница 2: ...Service Manual Removal Procedure Outdoor Unit zCooling Only RE50NRV16 RE60NRV16 REL50NRV16 REL60NRV16...

Страница 3: ...val Procedure 1 Table of Contents 1 Outer Panels 2 2 Outdoor Fan Fan Motor 3 3 Electrical Components 5 4 Capillary Tube 8 5 Compressor ASSY 10 Note The illustrations may be slightly different dependin...

Страница 4: ...e 4 screws and remove the top panel 2 Remove the 7 screws of the front panel 3 Unfasten the 2 hooks of the right side and remove the front panel 4 Remove the screw on the discharge grille 5 The discha...

Страница 5: ...itor C2 2 Pull out the 2 terminals black 3_upper green yellow _upper from the terminal board X1M 3 Release the fan motor lead wire from the hook 4 Remove the nut and remove the outdoor fan Nut size M6...

Страница 6: ...ut the fan motor lead wire through the back of the fan motor so as not to be entangled with the outdoor fan When reassembling fit the lower hooks into the bottom frame 6 Unfasten the 2 hooks and relea...

Страница 7: ...nts 1 Remove the right side panel The stop valve cover has 3 hooks 1 Remove the screw and remove the stop valve cover 2 Remove the 3 screws and remove the wire fixture 3 Remove the 7 screws on the ter...

Страница 8: ...e 5 Remove the 2 screws on the right side lower 6 Remove the 3 screws on the rear side 7 Unfasten the hook 8 Remove the right side panel The right side panel has 2 hooks at the bottom Step Procedure P...

Страница 9: ...ll out the terminal white 3_lower from the terminal board X1M 3 Remove the screw and remove the electrical component ASSY Step Procedure Points Compressor motor capacitor Terminal board R18997 white 3...

Страница 10: ...gaskets affected by heat Keep below 120 C 248 F For the sake of this wrap the four way valve with wet cloth and provide water so that the cloth does not dry Note Before working make sure that the ref...

Страница 11: ...oval Procedure 9 2 Remove the protection net 3 Heat up the 2 brazed parts and remove the capillary tube The design of capillary tube varies depending on the model Step Procedure Points Protection net...

Страница 12: ...ration of the gaskets affected by heat Keep below 120 C 248 F For the sake of this wrap the four way valve with wet cloth and provide water so that the cloth does not dry Note Before working make sure...

Страница 13: ...Pattern 2 S red C white R blue Pattern 3 S red C white R blue When reassembling fit the lower hook into the bottom frame 4 Remove the gasket 5 Remove the 3 screws and remove the partition plate Step P...

Страница 14: ...e compressor 7 Heat up the brazed part of the discharge side and disconnect 8 Heat up the brazed part of the suction side and disconnect 9 Lift the compressor ASSY up and remove it Step Procedure Poin...

Страница 15: ...Revision History Month Year Version Revised contents 06 2013 Si011281E First edition...

Страница 16: ...ries supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of parts and acce...

Отзывы: