Si011282EB
Electrical Components
Removal Procedure
5
3. Electrical Components
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Pull out the 5 terminals
from the capacitor.
2
Loosen the 2 screws of
the capacitor fixing
band and remove the
capacitor.
Capacitor
(R18568)
to compressor
(S): yellow
to compressor
(R): red
to terminal board
(2): black
to relay connector
for fan motor (1):
black
to relay
connector for
fan motor (3):
white
(R19170)
Capacitor
fixing band
(R18569)