Removal of Compressor ASSY
Si01-982
14
Removal Procedure
6. Removal of Compressor ASSY
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1
Remove the nut.
2
Remove the terminal
cover.
3
Disconnect the
compressor lead wires.
S (W): yellow
C (U): blue
R (V): red
4
Remove the gasket.
(R10482)
(R10483)
Terminal cover
(R17179)
Gasket
(R15375)
C (U)
R (V)
S (W)