Procedure to Remove Compressor
Si241307
6
Removal Procedure
3. Procedure to Remove Compressor
Procedure
Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
Make sure that refrigerant
is completely empty in the
circuit before
disassembling.
Warning
If refrigerant gas leaks during
servicing work, ventilate the
area. (If refrigerant gas
contacts flames, hazardous
gas can be generate.)
1
Disconnect the suction
pipe and the discharge
pipe of the compressor
at brazed sections.
Discharge
pipe
Suction pipe
Содержание R21NUV1
Страница 1: ...REMOVAL PROCEDURE S E R V I C E M A N U A L Outdoor Unit Non Inverter Pair Type 2 5 HP Class Si241307 ...
Страница 2: ...Service Manual Removal Procedure Outdoor Unit Applicable Models zCooling Only R21NUV1 ...
Страница 10: ...Revision History Month Year Version Revised contents 01 2013 Si241307 First edition ...