background image

RR-B7

Pair/Twin/Triple/Double Twin

Application

technical data 

Split
Sky Air

air 
conditioning 

systems

Содержание PR71B7W1B

Страница 1: ...RR B7 Pair Twin Triple Double Twin Application technical data Split Sky Air air conditioning systems...

Страница 2: ...the quality of the environment Daikin Europe N V is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard ISO9001 pertains to quality assurance regarding design de...

Страница 3: ...tings 9 3 Options 10 4 Capacity tables 11 Combination table 11 Cooling capacity tables 12 Cooling capacity tables simultaneous operation 18 5 Dimensional drawing centre of gravity 19 Dimensional drawi...

Страница 4: ...easily on a roof or terrace or simply placed against an outside wall Outdoor units are fitted with a scroll compressor renowned for low noise and high energy efficiency The piping connections can be...

Страница 5: ...t PE Fan Type Direct Drive Propeller Discharge direction Horizontal Quantity 1 1 1 1 2 Air Flow Rate nominal Cooling m3 min 48 0 48 0 55 0 55 0 89 0 Motor Quantity 1 1 1 1 1 Model P47L11S Position Low...

Страница 6: ...30 Installation height difference Maximum m 30 0 30 0 30 0 30 0 30 0 Max internunit level difference m 0 5 0 5 0 5 0 5 0 5 Heat Insulation Both liquid and gas pipes Defrost Method Reversed cycle Defr...

Страница 7: ...s earth wire included Power Supply Intake Outdoor unit only NOTES 1 Sound pressure level is a relative value depending on the distance and acoustic environment For more details please refer to sound l...

Страница 8: ...W1B 50 400 230 8 1 11 5 16 41 1 5 3 0 065 0 6 0 125 0 9 SYMBOLS MCA Min Circuit Amps TOCA Total Over Current Amps MFA Max Fuse Amps See note 7 LRA Locked Rotor Amps RLA Rated Load Amps OFM Outdoor Fan...

Страница 9: ...onnections see http www daikineurope com extranet select Daikin Documentation and select conditional connection the requested product type and English from the drop down lists click the search button...

Страница 10: ...rd fuse rating Min 16A 6 Select wire size based on the larger value of MCA or TOCA 7 Instead of fuse use circuit breaker 8 For more details concerning conditional connections see http www daikineurope...

Страница 11: ...RQ100B7V3B RR71B7V3B RR100B7V3B RQ71B7W1B RQ100B7W1B RQ125B7W1B RR71B7W1B RR100B7W1B RR125B7W1B Fan motor thermal protector Off 135 5 C On 95 15 C HPS Off 4 15 0 0 10 Mpa LPS Max discharge temperature...

Страница 12: ...27 3 3 Options Available option for RQ71 125B7 V3 W1 B and RR71 125B7 V3 W1 B 3TW26329 1 Name of option Kit name RQ71B7 RQ100B7 RQ125B7 RR71B7 RR100B7 RR125B7 Central drain plug KKPJ5F180 Refrigerant...

Страница 13: ...red Refnet kits mentioned that are necessary to install the combination 5 For unit specification of the outdoor units and the indoor units refer to the unit sepcifications mentioned for pair systems 6...

Страница 14: ...83 14 0 20 0 6 6 4 9 1 84 6 5 4 8 2 00 6 0 4 7 2 24 5 9 4 6 2 40 5 5 4 5 2 64 5 2 4 1 2 88 16 0 22 0 7 2 5 0 1 88 7 0 4 9 2 04 6 5 4 8 2 28 6 3 4 7 2 45 6 0 4 6 2 69 5 4 4 2 2 93 18 0 25 0 7 7 5 2 1...

Страница 15: ...fan motor Caution TC and SHC are shown by kW V1 V3 230 V 50 Hz W1 400 V 50 Hz NOTES 1 Ratings shown are net capacities Influence of fan motor heat is included 2 Shows nominal capacities 3 SHC is base...

Страница 16: ...or fan motor Caution TC and SHC are shown by kW V3 230 V 50 Hz W1 400 V 50 Hz NOTES 1 Ratings shown are net capacities Influence of fan motor heat is included 2 Shows nominal capacities 3 SHC is based...

Страница 17: ...7 4 4 9 2 49 7 2 4 7 2 67 6 7 4 6 2 94 6 2 4 4 3 20 22 0 30 0 8 7 5 3 2 09 8 5 5 2 2 27 8 0 5 1 2 54 7 9 4 8 2 72 7 4 4 7 2 99 6 7 4 4 3 27 24 0 32 0 9 4 5 3 2 11 9 1 5 2 2 29 8 6 5 1 2 57 8 4 4 9 2...

Страница 18: ...2 22 7 4 4 9 2 48 7 2 4 7 2 66 6 7 4 6 2 92 6 2 4 4 3 19 22 0 30 0 8 7 5 3 2 08 8 5 5 2 2 26 8 0 5 1 2 53 7 9 4 8 2 71 7 4 4 7 2 98 6 7 4 4 3 25 24 0 32 0 9 4 5 3 2 10 9 1 5 2 2 28 8 6 5 1 2 56 8 4 4...

Страница 19: ...s Corresponding refrigerant piping length 7 5m Level difference 0m 6 Air flow rate and BF are tabulated below Outdoor Indoor Outdoor temperature CDB EWB C EDB C 20 25 32 35 40 46 TC SHC PI TC SHC PI T...

Страница 20: ...8 24 0 32 0 9 4 1 99 9 1 2 16 8 6 2 42 8 4 2 59 8 0 2 85 7 4 3 11 9 4 1 99 9 1 2 16 8 6 2 42 8 4 2 59 8 0 2 85 7 4 3 11 100 12 0 18 0 8 4 2 53 8 3 2 80 8 1 3 16 7 8 3 34 7 5 3 70 6 8 4 15 8 4 2 53 8 3...

Страница 21: ...ding terminal M5 in switch box 5 Refrigerant piping intake 6 Power supply wiring intake knock out hole 34 7 Control wiring intake knock out hole 27 8 Drain outlet RR100B7 3TW26394 1 hole for anchor bo...

Страница 22: ...wing RR125B7 3TW26414 1 hole for anchor bolt 4 M12 LEGEND 1 Gas pipe connection 15 9 flare 2 Liquid pipe connection 9 5 flare 3 Service port in the unit 4 Grounding terminal M5 in switch box 5 Refrige...

Страница 23: ...27 5 Split Sky Air Outdoor Units 21 Outdoor Units R 410A RR B7 5 Dimensional drawing centre of gravity 5 2 Centre of gravity R Q R 71B7 3TW26329 5B R Q R 100B7 3TW26349 5B...

Страница 24: ...Outdoor Units R 410A RR B7 Split Sky Air Outdoor Units 22 27 5 5 Dimensional drawing centre of gravity 5 2 Centre of gravity R Q R 125B7 3TW26369 5B...

Страница 25: ...onnection Flange connection Pinched pipe Spinned pipe Filter Heat exchanger Indoor unit RR71 125B7 twin 3TW26375 2 Heat exchanger Electronic expansion valve Heat exchanger Filter Filter Field piping F...

Страница 26: ...ort 5 16 flare Field piping 9 5 C 1220T 0 Field piping 15 9 C 1220T 0 Service port 5 16 Heat exchanger Muffler High pressure switch Low pressure switch Filter Filter Receiver Solenoid valve Strainer C...

Страница 27: ...rminal BLK black BLU blue ORG orange RED red WHT white YLW yellow Live Neutral Connector Protective earth screw Terminal outdoor 71 100 class RR71 100B7W1B 2TW26386 1B LEGEND A1P Printed circuit board...

Страница 28: ...age breaker 30 mA Q1M Thermo switch M1F Q1RP Phase reverse circuit R1T Thermistor Air R2T Thermistor Coil R3T Thermistor Discharge pipe RC Signal receiver circuit S1PH Pressure switch high S1PL Pressu...

Страница 29: ...Air Outdoor Units 27 Outdoor Units R 410A RR B7 7 Wiring diagram 7 2 External connection diagram R Q R 71 125B7 4TW26329 7 I Pair II Twin III Triple M Master S Slave 1 Earth leak detector 2 Fuse 3 Rem...

Страница 30: ...tave band center frequency Hz Sound operation level dB Measuring location discharge side NOTES 1 Data is valid at free field condition 2 Data is valid at nominal operation condition 3 dBA A weighted s...

Страница 31: ...ing 3TW26347 3 Octave band center frequency Hz Sound operation level dB NOTE 1 Data is valid at free field condition 2 Data is valid at nominal operation condition 3 dBA A weighted sound operation lev...

Страница 32: ...0B7W1B RR125B7W1B 2 Depending on operation and installation conditions the indoor unit can change over to freeze up operation indoor de icing 3 To reduce the freeze up operation indoor de icing freque...