![Daikin Perfera RXM20R Скачать руководство пользователя страница 124](http://html1.mh-extra.com/html/daikin/perfera-rxm20r/perfera-rxm20r_service-manual_4700072124.webp)
4
|
Components
Service manual
124
RXM20~71R(9) + ARXM25~71R(9) + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11B – 2022.02
4.11.2 Repair procedures
To remove the intelligent eye sensor
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
153].
1
Remove the control panel from the indoor unit.
a
b
a
Control panel
b
Intelligent eye sensor PCB
2
Disconnect the connector from the intelligent eye sensor PCB.
3
Carefully click the complete intelligent eye sensor PCB out of the indoor unit.
4
To install the intelligent eye sensor PCB, see
To install the intelligent eye sensor
1
Click the intelligent eye sensor PCB on the indoor unit.
a
b
a
Control panel
b
Intelligent eye sensor PCB
2
Connect the harness to the intelligent eye sensor PCB.
3
Install the control panel on the indoor unit.
Is the problem solved?
Action
Yes
No further actions required.