Damper motor resistance
measurements are correct?
Action
No
3.4.2 Repair procedures
To remove the damper motor
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
1
Put a small drain pan (or container) under the drain hose.
2
Remove the screw from the fixation bracket and pull the drain hose
downwards to remove it from the indoor unit.
a
c
b
c
c
d
e
e
f
g
a
Screw (drain hose)
b
Drain hose
c
Screw (damper motor cover)
d
Damper motor cover
e
Screw (damper motor)
f
Damper motor
g
Damper motor wiring harness
3
Remove the 3 screws and remove the damper motor cover from the indoor
unit.
4
Remove the 2 screws to remove the damper motor from the cover.
5
Disconnect the damper motor wiring harness from the damper motor.
6
To install the damper motor, see
73].
To install the damper motor
1
Connect the damper motor wiring harness to the damper motor.
2
Install the damper motor in the correct location on the damper motor cover.
Fix the damper moto to the cover using the 2 screws.