5-room centralised
controller
KRC72
Remote controller loss
prevention with chain
KKF917A4
Options
Specifications
Titanium apatite photocatalytic
air-purifying filter
KAF970A48
Measurement conditions
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m.
2. Sound pressure levels are measured in an anechoic chamber based on temperature condition 1 above. These values are normally
somewhat higher during actual
operation as a result of ambient conditions.
Note: The above values are based on operation with a 220V, 60Hz power suuply.
Outdoor unit
Control system
No.
1
2
Item
Air direction adjustment grille
Drain plug
Note: *1. One set includes 5 pieces for 5 units.
Central remote controller
DCS302CA61
Unified On/Off controller
DCS301BA61
Schedule timer
DST301BA61
Air direction adjustment grille
KPW945A4
Drain plug
KKP945A4
Drain plug
KKP937A4
No.
1
2
3
4
Item
Central remote controller
Unified On/Off controller
Schedule timer
Interface adaptor for DIII-NET use
Note: *1. Interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit.
*
1
*
1
*
1
*
1
Titanium apatite photocatalytic
air-purifying filter
KAF970A46
DCS302CA61
DCS301BA61
DST301BA61
KRP928BB2S
FTKS25/35G, FTKS50/60/71/85H
RKS50/60H
RKS71H
RKS85H
KPW5E112
RKS25/35EB
KPW937A4
Indoor unit
Notes: *1. The 3m (BRCW901A03) - or 8m (BRCW901A08) - length wired remote controller cord is required.
*2. A wiring adaptor (KRP413AB1S) is also required for each indoor unit.
*3. The time clock and other devices should be obtained locally.
*4. The filter is a standard accessory. It should be replaced approximately every 3 years.
No.
1
2
3
4
5
6
FTKS71/85H
KAF970A48
FTKS50/60H
KRC72
KRP413AB1S
KKF917A4
FTKS25/35G
BRC944B2
BRCW901A03
BRCW901A08
*
1
*
2
*
3
*
4
Specifications are subject to change.
Item
Wired remote controller
Wired remote controller cord
5-room centralised controller
Wiring adaptor for time clock/remote controller
(Normal open pulse contact/normal open contact)
Titanium apatite photocatalytic air-purifying filter
Remote controller loss prevention with chain
KPW945A4
–
–
–
KAF970A46
Length 3 m (shielded wire)
Length 8 m (shielded wire)
4
A
5
4
9
P
K
K
4
A
7
3
9
P
K
K
FTKS71/85H
Indoor unit
Outdoor unit
Model name
Capacity
Power supply
Running current
Power consumption
COP
Indoor unit
Front panel colour
Airflow rate (H)
Fan speed
Sound pressure level (H/L/SL)
Dimensions (H x W x D)
Machine weight
Outdoor unit
Casing colour
Compressor
Refrigerant charge (R-410A)
Sound pressure level (H/SL)
Dimensions (H x W x D)
Machine weight
Operation range
Piping
connection
Max. piping length
Max. height difference
Rated (Min.-Max.)
Rated
Rated
Rated
Motor output
FTKS71HVM
RKS71HVM
7.1 (2.7-8.7)
24,200 (9,200-29,700)
9.6
2,060
3.45
FTKS71HVM
21.7 (766)
46/37/34
RKS71HVM
1,920
2.0
52/49
770 x 900 x 320
60
15
FTKS85HVM
RKS85HVM
8.5 (3.0-9.7)
29,000 (10,200-33,100)
11.6
2,540
3.35
FTKS85HVM
23.0 (812)
49/40/37
RKS85HVM
2,030
2.7
55/52
990 x 940 x 320
73
20
O.D. 16.0
30
Liquid
Gas
Drain
White
5 steps, quiet and automatic
340 x 1,200 x 240
17
Ivory white
Hermetically sealed swing type
19.4 to 46
9.5
15.9
kW
Btu/h
A
W
W/W
m
3
/min (cfm)
dB (A)
mm
kg
W
kg
dB (A)
mm
kg
CDB
mm
m
1 phase, 220-240 V / 220-230 V, 50/60 Hz
Type