18
Troubleshooting
Before making an inquiry or a request for repair, please check the following.
If the problem persists, contact the place of purchase.
In the event of malfunction during operation
If the indicator lamps light up abnormally, or become inoperable, due to a lightning strike etc., remove the
power supply plug, wait at least 5 seconds then reinsert the power supply plug and turn the unit on again.
Not a problem
This case is not a problem.
Check
Please check again before requesting
repairs.
Unit does not respond
Phenomenon
Check points
No response even if
is
pressed
• To protect the system, the unit may stop operating after
sudden large voltage fluctuations.
If operating at the time, operation will resume automatically
once voltage returns to normal.
Voltage range protection: 198V-264V
Sounds can be heard
Phenomenon
Check points
Hissing sound during
operation
While the Streamer is operating, the Streamer unit will emit a
hissing sound when conducting Streamer discharge.
Depending on usage, the sound may fall in volume or change to
a crackling, whirring, or guzzling sound. However, this is normal.
If the sounds are an issue, try moving the unit to a different
location.
►
Page 12
Whistling and fluttering sound
during operation
•
Is there a buildup of dust on the pre-filters?
¼
Clean this part.
►
Page 13
•
Is the dust collection filter clogged up?
¼
Depending on usage conditions, the dust collection filter
may become clogged up, shortening its service life.
►
Page 7
Replace the dust collection filter.
►
Page 14
Operating sound is loud
•
Is the dust collection filter attached properly?
¼
If it is not properly attached, operating sounds may become
louder.
►
Page 14
Indicator lamps
Phenomenon
Check points
Indicator lamps do not light up
Indicator lamps turn off about
10 seconds after the unit is
turned on
•
Is indicator lamp brightness set to OFF?
¼
If indicator lamp brightness is set to OFF, all lamps except
the ON-OFF lamp will remain off.
¼
If indicator lamp brightness is set to OFF, after the unit is
turned on, the brightness of the indicator lamps will be DIM
for about 10 seconds and then turn OFF.
►
Page 11
Troubleshooting
Содержание MC30YVM
Страница 23: ......