background image

English 3

f

 

a

b

c

d

e

a  Fasten the terminals with care to
 

prevent the wires from touching each other

b  Clamp (knot)
c  Extension cable
d  Sheathed part
e  Sensor box
f  Clamp hole

•  Screw the sensor box securely to the wall surface with screws M4X16 (2 
places). If the sensor box cannot be screwed to the wall surface, tear off  the 
released paper and mount it on the wall surface. 

For embedded wiring

a

b

c

d

e

f

g

h

i

j

k

l

a  Sensor box cover
b  Mounting screw
c  Sensor box
d  Metal plate (for single unit
 

without hole), (fi eld supplied)

e  Mounting frame which matches with
 

the switch box (fi eld supplied)

f  Switch box (for single unit), (fi eld
 

supplied)

g  Extension cable
h  Through hole
i   Sheathed part
j   Clamp (knot)
k  Sensor box
l  Thermal insulation material

•  Pass the extension cable through the switch box cable hole and carry out 
the wiring.
•  Pass the attached clamp through the clamp holes and tighten the 
extension cable at the sheathed part as shown in the upper right fi gure.

Содержание KRCS01-8B

Страница 1: ...Remote sensor KRCS01 8B Installation Manual 4P587492 1...

Страница 2: ......

Страница 3: ...x Mounting Selection of mounting location The thermistor for temperature detection is incorporate into the remote sensor Select the mounting location taking following cautions into account Where the a...

Страница 4: ...ll a b c d e f g a Mounting screw b Thermal insulation material c Knockout hole for cable d Sensor box e Air hole f Released paper g Sensor box cover 2 M4 32 42 Break open the knockout hole in the sen...

Страница 5: ...bedded wiring a b c d e f g h i j k l a Sensor box cover b Mounting screw c Sensor box d Metal plate for single unit without hole eld supplied e Mounting frame which matches with the switch box eld su...

Страница 6: ...hat the connector side may not be cut 45 For M3 Round crimp terminal Wiring method Connect the extension cable connector side to the indoor unit PCB printed circuit board For connection to the indoor...

Страница 7: ...h box may be a ected by the power line cord for the indoor unit and the other electric line Procedure 1 When wiring to the indoor unit PCB remove the existing thermistor for detection of inlet air tem...

Страница 8: ...etween the high voltage wiring and the low voltage wiring to avoid error of sensor Provide protection of the existing cable for thermistor without a ecting other components 3 Fit the sensor box cover...

Страница 9: ......

Страница 10: ...4P587492 1 2019 07...

Отзывы: