Daikin KEH094A41E Скачать руководство пользователя страница 3

1

2

3

View 

A

A

Remove 2 screws. (Hexagon tapping screw)

Installation Procedure (3)

Installation Procedure (3)

Installation Procedure (2)

Installation Procedure (2)

4.  Route the harnesses.

6.  Install each component to the original position.

2)  Connect the black harness to the leftmost terminal and the white harness to the second leftmost 

terminal.

• Be careful not to confuse screw types. Refer to “

Installation Procedure (1)

 ”.

1)  Remove 2 screws from the bottom frame so that the plates of the drain pan heater can be inserted under the heat 

exchanger with ease.

2)  Lift up the heat exchanger and insert the plates of the      drain pan heater under the heat exchanger.

• 

The ground plate of the drain pan heater should be installed so that it firmly adheres to the bottom frame.

• Install the drain pan heater in a position where it does not come into contact with the fan motor base.

3)  Fix the      drain pan heater with the      screws.

 

(3 locations) 

A

A

B

5.  Cut the jumper.

CAUTION

• When drilling a hole, be careful not to damage the soundproofing material and other components on the back side.

3.  Install the      drain pan heater.

A

1)  Flex the sheet metal of the outdoor unit and pull the harness around.

1)  Remove the electrical wiring box cover.
2)  Cut the jumper (J9) of the PCB inside.

View 

B

Holes
(2 locations)

Partition 
plate

Ground plate
(The ground plate should be 

installed so that it firmly 

adheres to the partition plate.)

Secure with cable ties (3 locations)

Black harness

White harness

Hook
(3 places)

Cut the jumper (J9)

Electrical wiring box cover

B

Pass the harness 
through the slit in the 
electrical wiring box

Secure with      cable tie

C

Plate (Insert the plate under the heat exchanger.)

 Drain pan heater

A

Hole (Fix with the      screw.)

B

Heat exchanger

 Screws

B

01_EN_3P647274-1.indd   2

2021/02/25   13:50:57