C
B
1) Drill a ø5/32” (ø4mm) hole in the partition plate for installing the snap band. (1 location)
2) Insert the snap band into the drilled hole.
3) Cut off the electrical wiring box and affix F sealing materials (square) at 2 positions to protect the
harness.
4) Place the harness and affix the E sealing material (long) to fix it.
5) Insert the snap band into the hole in the electrical wiring box to fix it.
• Any of the holes can be used.
6) Fix the harness on the electrical wiring box with the D binding band.
• Cut the tip of binding band.
F
E
KEH041A43
Installation Procedure (4)
3.
Route the harnesses.
• When drilling a hole, be careful not to damage the soundproofing material and other components on the
back side.
• When drilling a hole in the partition plate, be careful not to let chippings drop on the electrical components
(particularly the reactor).
Operating the unit with chippings attached on the reactor may cause electrical shock or fire.
WARNING
D Binding band
E Sealing material
(long)
Snap band
F Sealing materials
(square)
View
C
View
B
Hole:
Drill a hole in alignment with the
actual component and at a
position where the harness will
not become loose or too tense.
Cut the
electrical
wiring box
Any of the holes
can be used.
Snap band
D