11

To change the air flow rate setting

5. Press “FAN setting button”.

• Indoor unit quiet operation

When the air flow is set to “

”, the noise from the indoor unit will become quieter. 

Use this when making the noise quieter.
The unit might lose capacity when the air flow rate is set to a weak level.

NOTE

DRY mode

AUTO or COOL or HEAT or FAN mode

The air flow rate setting is not variable.

Five levels of air flow rate setting from “ ” to “

plus “

” “

” are available.

Note on HEAT operation

• Since this air conditioner heats the room by taking heat from outdoor air to indoors, the 

heating capacity becomes smaller in lower outdoor temperatures.  If the heating effect is 
insufficient, it is recommended to use another heating appliance in combination with the air 
conditioner.

• The heat pump system heats the room by circulating hot air around all parts of the room.  

After the start of heating operation, it takes some time before the room gets warmer.

• In heating operation, frost may occur on the outdoor unit and lower the heating capacity.  In 

that case, the system switches into defrosting operation to take away the frost.

• During defrosting operation, hot air does not flow out of indoor unit.

Note on COOL operation

• This air conditioner cools the room by blowing the hot air in the room outside, so if the out-

side temperature is high, performance drops.

Note on DRY operation

• The computer chip works to rid the room of humidity while maintaining the temperature as 

much as possible. It automatically controls temperature and fan strength, so manual 
adjustment of these functions is unavailable.

Note on AUTO operation

• In AUTO operation, the system selects a temperature setting and an appropriate operation 

mode (COOL or HEAT) based on the room temperature at the start of the operation.

• The system automatically reselects setting at a regular interval to bring the room tempera-

ture to user-setting level.

• If you do not like AUTO operation, you can manually select the operation mode and setting 

you like.

Note on air flow rate setting

• At smaller air flow rates, the cooling (heating) effect is also smaller.

01_EN_3P194444-5D.fm  Page 11  Wednesday, August 21, 2013  7:00 PM

Содержание Inverter FLXS25BVMB

Страница 1: ...5BVMB FLKS35BVMB FLXS50BVMB FLKS50BVMB FLXS60BVMB FLKS60BVMB FLXS25BAVMB FLKS25BAVMB FLXS35BAVMB FLKS35BAVMB FLXS50BAVMB FLKS50BAVMB FLXS60BAVMB FLKS60BAVMB FLXS35BAVMB9 MODELS DAIKIN ROOM AIR CONDITI...

Страница 2: ...ow Direction 12 POWERFUL Operation 14 OUTDOOR UNIT QUIET Operation 15 HOME LEAVE Operation 16 TIMER Operation 18 Note for Multi System 20 CARE Care and Cleaning 22 TROUBLE SHOOTING Trouble Shooting 25...

Страница 3: ...mpt to install the air conditioner by your self Incorrect work will result in water leakage electric shocks or fire For installation consult the dealer or a qualified technician In order to avoid elec...

Страница 4: ...for small animals which can enter the unit Once in the unit such animals can cause malfunctions smoke or fire when making contact with electrical parts Do not operate the air conditioner with wet hand...

Страница 5: ...ation is being carried out to the ceiling The methods of operation used are the same when installing to a wall Opening the front panel How to open the front panel page 22 CAUTION Before opening the fr...

Страница 6: ...to stop it The operation mode refers to the following table Push the switch using an object with a sharp tip such as a pen This switch is useful when the remote controller is missing 14 Signal receiv...

Страница 7: ...to stop it 7 MODE selector button It selects the operation mode AUTO DRY COOL HEAT FAN page 10 8 QUIET button OUTDOOR UNIT QUIET operation page 15 9 FAN setting button It selects the air flow rate set...

Страница 8: ...ong time take the batteries out The batteries will last for approximately one year If the remote controller display begins to fade and the degradation of reception performance occurs within a year how...

Страница 9: ...cation with the screws procured locally 3 Place the remote controller in the remote controller holder ATTENTION About remote controller Never expose the remote controller to direct sunlight Dust on th...

Страница 10: ...ion outside this humidity or temperature range may cause a safety device to disable the system C TEMP ON OFF POWERFUL HOME LEAVE MODE FAN SWING QUIET 1 3 2 Recommended temperature setting For cooling...

Страница 11: ...AUTO DRY COOL HEAT FAN 2 Press ON OFF button The OPERATION lamp lights up To stop operation 3 Press ON OFF button again Then OPERATION lamp goes off To change the temperature setting 4 Press TEMPERATU...

Страница 12: ...outdoor unit and lower the heating capacity In that case the system switches into defrosting operation to take away the frost During defrosting operation hot air does not flow out of indoor unit Note...

Страница 13: ...1 Press SWING button is displayed on the LCD and the flaps will begin to swing 2 When the flaps have reached the desired position press SWING button once more The flap will stop moving disappears fro...

Страница 14: ...ngle in COOL or DRY mode to obtain the best performance In COOL or DRY mode if the flap is fixed at a downward position the flap automatically moves in about 60 minutes to prevent condensation on it A...

Страница 15: ...eration 2 Press POWERFUL button again disappears from the LCD NOTE Notes on POWERFUL operation In COOL and HEAT mode To maximize the cooling heating effect the capacity of outdoor unit must be increas...

Страница 16: ...OUTDOOR UNIT QUIET operation is set on all operated indoor units However if using priority room setting see Note for multi system page 20 This function is available in COOL HEAT and AUTO modes This i...

Страница 17: ...and air flow rate for HOME LEAVE operation Record your preferred temperature and air flow rate 1 Press HOME LEAVE button Make sure is displayed in the remote control ler display 2 Adjust the set tempe...

Страница 18: ...Push the HOME LEAVE Opera tion button again and the air condi tioner will adjust capacity to the set temperature for normal operation Set the unit to HOME LEAVE Operation before leaving the liv ing ro...

Страница 19: ...n again The TIMER lamp lights up To cancel the OFF TIMER operation 4 Press CANCEL button The TIMER lamp goes off NOTE When TIMER is set the present time is not displayed Once you set ON OFF TIMER the...

Страница 20: ...on again The TIMER lamp lights up To cancel ON TIMER operation 4 Press CANCEL button The TIMER lamp goes off To combine ON TIMER and OFF TIMER A sample setting for combining the two timers is shown be...

Страница 21: ...Please consult your retailer or dealer for assistance NIGHT QUIET Mode reduces the operation noise of the outdoor unit during the night time hours to prevent annoyance to neighbors The NIGHT QUIET Mo...

Страница 22: ...POWERFUL operation operation capacity will be concentrated in Room A In such a case the cooling heating efficiency of the units in Rooms B C and D may be slightly reduced 3 Priority when using OUTDOOR...

Страница 23: ...trou bles as dust will accumulate inside the indoor unit CAUTION Units Don t touch the metal parts of the indoor unit If you touch those parts this may cause an injury When removing or attaching the f...

Страница 24: ...e It is recommended to clean the air filters every two weeks Air Purifying Filter green Replace approximately once every 3 months 1 Detach the filter element and attach a new one Insert with the green...

Страница 25: ...er vice shop if this is the case Operation with dirty filters 1 cannot deodorize the air 2 cannot clean the air 3 results in poor heating or cooling 4 may cause odour The air purifying filter and Phot...

Страница 26: ...on In COOL or DRY mode Moisture in the air condenses into water on the cool surface of outdoor unit piping and drips Mist comes out of the indoor unit This happens when the air in the room is cooled i...

Страница 27: ...air filters or take all obstacles away and turn the breaker OFF Then turn it ON again and try operating the air conditioner with the remote controller If the lamp still blinks call the service shop w...

Страница 28: ...cialized treatment facility for re use recycling and recovery By ensuring correct disposal you will help to prevent potential negative consequences for the environment and human health Please contact...

Страница 29: ...OUTDOOR UNIT EA COOLING HEATING SWITCHING ERROR E5 OL STARTED E6 FAULTY COMPRESSOR START UP E7 DC FAN MOTOR FAULT E8 OPERATION HALT DUE TO DETECTION OF INPUT OVER CURRENT F3 HIGH TEMPERATURE DISCHARG...

Страница 30: ...UNIT FAULTY COMPRESSOR START INPUT OVERCURRENT HIGH TEMPERATURE SWITCHBOX HIGH TEMPERATURE AT INVERTER CIRCUIT HEATSINK LOW VOLTAGE TO MAIN CIRCUIT OR MOMENTARY VOLTAGE LOSS REVERSING SOLENOID VALVE...

Страница 31: ...30 MEMO 01_EN_3P194444 5D fm Page 30 Wednesday August 21 2013 7 00 PM...

Страница 32: ...1309 HT 3P194444 5D M06B204D Two dimensional bar code is a code for manufacturing 00_CV_3P194444 5D fm Page 2 Wednesday August 21 2013 6 59 PM...

Отзывы: