Installation and operation manual
34
125A8V1BF
VRV IV System indoor unit
4P405267-1C – 2021.04
Programming
Programming space cooling
Programming space cooling is carried out as follows:
1
Press the button to enter the programming/consulting mode.
2
Select the operation mode you would like to program by means
of the
and
buttons.
The actual mode is blinking.
3
Press the button to confirm the selected mode.
The time is blinking.
4
Consult the action by means of the
and
buttons.
5
Hold down the button for 5 seconds to program the detailed
actions.
The first programmed action appears.
6
Use the button to select the action number you would like to
program or to modify.
7
Use the
and
buttons to set the correct action time.
8
Use the
and
buttons to set the leaving water
temperature.
9
Use the
and
buttons to set the room temperature.
10
Use the
button to select
to switch cooling and the user
interface off.
11
Repeat steps
When all actions have been programmed, make sure that the
display shows the highest action number you would like to save.
12
Press the button for 5 seconds to store the programmed
actions.
If the button is pressed when action number 3 is displayed,
actions 1, 2 and 3 are stored but 4 is deleted.
You automatically return to step
By pressing the
button several times, you return to previous
steps in this procedure and finally return to normal operation.
13
You automatically return to step
, start again to program the
following day.
5 sec
5 sec
INFORMATION
Returning to previous steps in the programming procedure
without saving modified settings is done by pressing the
button.
Содержание HXY080A8V1BF
Страница 1: ...INSTALLATION AND OPERATION MANUAL HXY080A8V1BF HXY125A8V1BF System indoor unit...
Страница 46: ......
Страница 47: ......
Страница 48: ...4P405267 1C 2021 04 Copyright 2021 Daikin 3...