Outdoor Unit - RK(X)S20-35G2V1B9, ARXS20-35G3V1B
SiBE04-808_B
227
Removal Procedure
14
Remove the 6 screws.
15
Unfasten the 4 hooks
and remove the main
PCB.
Refer to page 24 for detail.
[S10] [HL3] [HN3]: filter PCB
[S20]: electronic
expansion
valve coil
[S40]: overload
protector
[S50]: magnetic
relay
[S70]: fan
motor
[S80]: four way valve coil
[S90]: thermistors
[S100]: forced operation button
PCB
Step
Procedure
Points
(R11866)
(R11867)
(R11868)
[S50]
[S100]
[S90]
[S10]
[HN3]
[HL3]
[S80]
[S20]
[S40]
[S70]