EDUS391777-F17
Installation Manual
FXSQ-TAVJU
6
3P184443-13Z
6
English
Control box
13/16 (20)
or more
Ceiling
Inspection hatch
A
Inspection
hatch 1
17-3/4×17-3/4
(450×450)
Inspection
hatch 3
Control box
Control box
31-1/2
(800)
31-1/2
(800)
Arrow A-1
Arrow A-2
Inspection hatch 2
(Indoor unit size
+11-13/16 (300)
or more)
(Indoor unit
size or more)
7-7/8 (200)
or less
D=B+11-13/16
(300) or more
B
< In the case of (1)-2, 3 >
Fig. 4
Table 1
(unit [in. (mm)])
Model
B
C
D
05·07·09·12 type
21-5/8 (550)
23-1/8 (588)
33-7/16
(850)
15 type
27-9/16
(700)
29-1/16
(738)
39-3/8
(1000)
18·24·30 type
39-3/8
(1000)
40-7/8
(1038)
51-3/16
(1300)
36·48 type
55-1/8
(1400)
56-5/8
(1438)
66-15/16
(1700)
54 type
61 (1550)
62-1/2 (1588)
72-13/16
(1850)
(2) Mount canvas ducts to the air outlet and inlet so that
the vibration of the indoor unit will not be transmitted
to the ducts or ceiling. Furthermore, attach sound
absorbing material (thermal insulation material) to
the duct inner walls and anti-vibration rubber to the
hanging bolts (refer to 8. DUCT WORK).
(3) The indoor unit is set to standard external static
pressure.
r
+HGZVGTPCNUVCVKERTGUUWTGKUJKIJGTQTNQYGTVJCPVJG
standard set value, the remote controller may be used
VQOCMGƂGNFUGVVKPIEJCPIGKPVJGGZVGTPCNUVCVKERTGU
-
sure.
Refer to
10. FIELD SETTING
.
(4) Open installation holes
(in the case of installation onto the existing ceiling).
r
Open the installation holes on the ceiling of the instal-
lation location, and work on the refrigerant piping, drain
piping, remote controller wiring (unless a wireless re-
mote controller is used), and wiring between the indoor
and outdoor units to the piping connection port and
wiring connection port of the indoor unit (refer to each
piping and wiring procedure items).
r
Ceiling framework reinforcement may be required in
order to keep the ceiling horizontal and prevent ceiling
vibration after opening the ceiling holes. For details,
consult your building and upholstery work contractors.
(5) Install the hanging bolts.
r
Use either a M8-M10 size bolt or equivalent.
7UGJQNGKPCPEJQTUHQTVJGGZKUVKPIDQNVUCPFGODGF
-
FGFKPUGTVUQTHQWPFCVKQPDQNVUHQTPGYDQNVUCPFƂZVJG
KPFQQTWPKVƂTON[VQVJGDWKNFKPIUQVJCVKVOC[YKVJUVCPF
the weight of the unit.
In addition, adjust clearance (2-4 in. (50-100 mm)) from
the ceiling in advance.
+PUVCNNCVKQPGZCORNGU
Foundation bolt
Hanging bolt
Indoor
unit
Ceiling slab
Long nut or
turnbuckle
0QVG%QORQPGPVUUJQYPKPVJGƂIWTGCDQXGCTG
all local procurement.
(6) In the case of changing the preset suction to bottom
side suction, replace the chamber cover and the suc-
VKQPƃCPIG4GHGTVQ(KI
4GOQXGVJGUWEVKQPƃCPIGCPFEJCODGTEQXGT
4GRNCEGVJGUWEVKQPƃCPIGCPFVJGEJCODGTEQXGT
CAUTION
r
5GEWTGCUWHƂEKGPVUGTXKEGURCEGHQTVJGFTCKPRCPCPF
electrical components before installing the indoor unit.
r
5GEWTGCUWHƂEKGPVUGTXKEGURCEGHQTVJGƂNVGTEJCODGT
and peripheral components before installing the indoor
unit.
Содержание FXSQ05TAVJU
Страница 1: ...EDUS391777 F17 FXSQ TAVJU MSP Concealed Ducted Unit...
Страница 2: ......
Страница 11: ...EDUS391777 F17 Dimensions FXSQ TAVJU 9 3 Dimensions FXSQ05TAVJU FXSQ07TAVJU FXSQ09TAVJU FXSQ12TAVJU 3D110730A...
Страница 12: ...Dimensions EDUS391777 F17 10 FXSQ TAVJU FXSQ15TAVJU 3D110731A...
Страница 13: ...EDUS391777 F17 Dimensions FXSQ TAVJU 11 FXSQ18TAVJU 3D110732A...
Страница 14: ...Dimensions EDUS391777 F17 12 FXSQ TAVJU FXSQ24TAVJU FXSQ30TAVJU 3D110733B...
Страница 15: ...EDUS391777 F17 Dimensions FXSQ TAVJU 13 FXSQ36TAVJU FXSQ48TAVJU 3D110734B...
Страница 16: ...Dimensions EDUS391777 F17 14 FXSQ TAVJU FXSQ54TAVJU 3D110735B...
Страница 23: ...EDUS391777 F17 Fan Performance FXSQ TAVJU 21 9 Fan Performance FXSQ05TAVJU FXSQ07TAVJU 3D113374A...
Страница 24: ...Fan Performance EDUS391777 F17 22 FXSQ TAVJU FXSQ09TAVJU 3D112417...
Страница 25: ...EDUS391777 F17 Fan Performance FXSQ TAVJU 23 FXSQ12TAVJU 3D112418...
Страница 26: ...Fan Performance EDUS391777 F17 24 FXSQ TAVJU FXSQ15TAVJU 3D112419...
Страница 27: ...EDUS391777 F17 Fan Performance FXSQ TAVJU 25 FXSQ18TAVJU 3D112420...
Страница 28: ...Fan Performance EDUS391777 F17 26 FXSQ TAVJU FXSQ24TAVJU 3D112421...
Страница 29: ...EDUS391777 F17 Fan Performance FXSQ TAVJU 27 FXSQ30TAVJU 3D112422...
Страница 30: ...Fan Performance EDUS391777 F17 28 FXSQ TAVJU FXSQ36TAVJU 3D112423...
Страница 31: ...EDUS391777 F17 Fan Performance FXSQ TAVJU 29 FXSQ48TAVJU 3D112424...
Страница 32: ...Fan Performance EDUS391777 F17 30 FXSQ TAVJU FXSQ54TAVJU 3D112425...
Страница 34: ...Airflow Auto Adjustment Characteristics EDUS391777 F17 32 FXSQ TAVJU FXSQ09TAVJU 3D112454...
Страница 35: ...EDUS391777 F17 Airflow Auto Adjustment Characteristics FXSQ TAVJU 33 FXSQ12TAVJU 3D112455...
Страница 36: ...Airflow Auto Adjustment Characteristics EDUS391777 F17 34 FXSQ TAVJU FXSQ15TAVJU 3D112456...
Страница 37: ...EDUS391777 F17 Airflow Auto Adjustment Characteristics FXSQ TAVJU 35 FXSQ18TAVJU 3D112457...
Страница 38: ...Airflow Auto Adjustment Characteristics EDUS391777 F17 36 FXSQ TAVJU FXSQ24TAVJU 3D112458...
Страница 39: ...EDUS391777 F17 Airflow Auto Adjustment Characteristics FXSQ TAVJU 37 FXSQ30TAVJU 3D112459...
Страница 40: ...Airflow Auto Adjustment Characteristics EDUS391777 F17 38 FXSQ TAVJU FXSQ36TAVJU 3D112460...
Страница 41: ...EDUS391777 F17 Airflow Auto Adjustment Characteristics FXSQ TAVJU 39 FXSQ48TAVJU 3D112461...
Страница 42: ...Airflow Auto Adjustment Characteristics EDUS391777 F17 40 FXSQ TAVJU FXSQ54TAVJU 3D112462...
Страница 44: ...Sound Levels Reference Data EDUS391777 F17 42 FXSQ TAVJU FXSQ12TAVJU 4D110413...
Страница 45: ...EDUS391777 F17 Sound Levels Reference Data FXSQ TAVJU 43 FXSQ15TAVJU 4D110414...
Страница 46: ...Sound Levels Reference Data EDUS391777 F17 44 FXSQ TAVJU FXSQ18TAVJU 4D110415...
Страница 47: ...EDUS391777 F17 Sound Levels Reference Data FXSQ TAVJU 45 FXSQ24TAVJU 4D110416...
Страница 48: ...Sound Levels Reference Data EDUS391777 F17 46 FXSQ TAVJU FXSQ30TAVJU 4D110417...
Страница 49: ...EDUS391777 F17 Sound Levels Reference Data FXSQ TAVJU 47 FXSQ36TAVJU 4D110418...
Страница 50: ...Sound Levels Reference Data EDUS391777 F17 48 FXSQ TAVJU FXSQ48TAVJU 4D110419...
Страница 51: ...EDUS391777 F17 Sound Levels Reference Data FXSQ TAVJU 49 FXSQ54TAVJU 4D110420...
Страница 55: ...EDUS391777 F17 Appendix 1 FXSQ TAVJU A1 Appendix 1 Installation of FXSQ TAVJU 1 Installation Manual 1...
Страница 75: ......