• Indoor Unit • FXLQ-P
10
• VRV Systems • FXLQ-P
16
10
Sound data
10 - 1 Sound Pressure Spectrum
NOTES
1
Over all (dB):
(B, G, N is already rectified)
2
Measuring place: Anechoic chamber
3
Operating conditons:
•
Power source: 220•240V/220V 50/60Hz
•
JIS standard
4
Location of microphone
5
Operating noise differs with operation and ambient conditions.
FXLQ20,25P
4D034528A
Approximate
threshold hearing for
continuous noise
Octave band center frequency (Hz)
Octave band sound pressure level d
B
(0
dB=0.00
02
μ
bar)
Scale
220V
240V
H
L
H
L
A
35
32
37
34
C
40
36.5
42
38.5
220V
240V
1.5m
1.5m
Microphone
NOTES
1
Over all (dB):
(B, G, N is already rectified)
2
Measuring place: Anechoic chamber
3
Operating conditons:
•
Power source: 220•240V/220V 50/60Hz
•
JIS standard
4
Location of microphone
5
Operating noise differs with operation and ambient conditions.
FXLQ32P
4D034564A
Approximate
threshold hearing for
continuous noise
Octave band center frequency (Hz)
Octave band sound pressure level d
B
(0
dB=0.00
02
μ
bar)
Scale
220V
240V
H
L
H
L
A
35
32
37
34
C
39
37
41
39
220V
240V
1.5m
1.5m
Microphone
NOTES
1
Over all (dB):
(B, G, N is already rectified)
2
Measuring place: Anechoic chamber
3
Operating conditons:
•
Power source: 220•240V/220V 50/60Hz
•
JIS standard
4
Location of microphone
5
Operating noise differs with operation and ambient conditions.
FXLQ40P
4D034565A
Approximate
threshold hearing for
continuous noise
Octave band center frequency (Hz)
Octave band sound pressure level d
B
(0
dB=0.00
02
μ
bar)
Scale
220V
240V
H
L
H
L
A
38
33
40
35
C
42
38
44
40
220V
240V
1.5m
1.5m
Microphone
NOTES
1
Over all (dB):
(B, G, N is already rectified)
2
Measuring place: Anechoic chamber
3
Operating conditons:
•
Power source: 220•240V/220V 50/60Hz
•
JIS standard
4
Location of microphone
5
Operating noise differs with operation and ambient conditions.
FXLQ50P
4D034566A
Approximate
threshold hearing for
continuous noise
Octave band center frequency (Hz)
Octave band sound pressure level d
B
(0
dB=0.00
02
μ
bar)
Scale
220V
240V
H
L
H
L
A
39
34
41
36
C
44
38.5
46
40.5
220V
240V
1.5m
1.5m
Microphone
Содержание FXLQ-P
Страница 1: ...Air Conditioning Technical Data Floor standing unit EEDEN14 204 FXLQ P...
Страница 2: ......
Страница 7: ...3 3 VRV Systems FXLQ P 5 Indoor Unit FXLQ P 3 Safety device settings 3 1 Safety Device Settings...
Страница 15: ...3 7 VRV Systems FXLQ P 13 Indoor Unit FXLQ P 7 Centre of gravity 7 1 Centre of Gravity 7 4 3 0RGHO 4 3 4 3 4 3...
Страница 16: ...Indoor Unit FXLQ P 8 VRV Systems FXLQ P 14 8 Piping diagrams 8 1 Piping Diagrams 4D034245G...
Страница 20: ......