English
11
10. DECORATION PANEL INSTALLATION
Refer to the installation manual of the panels.
[ PRECAUTIONS ]
•
SWING FLAP MOTOR WIRING METHOD
(1)
CONNECT TWO LEAD WIRES OF SWING FLAP MOTOR
MOUNTED ON THE DECORATION PANEL TO THE CON-
NECTORS OF MAIN BODY.
(2)
SLIDE THE INSULATION TUBE ACCORDING TO THE
ARROW AS SHOWN IN FIG. SO THAT THE CONNEC-
TOR CAN BE COMPLETELY COVERED.
(3)
BIND THE OPENING OF INSULATION TUBE WITH THE
ATTACHED CLAMP MATERIAL.
11. FIELD SETTING
Make sure the terminal box lids are closed on the indoor
and outdoor units.
Field setting must be made from the remote controller in
accordance with the installation condition.
• Setting can be made by changing the “Mode No.”, “FIRST
CODE NO.”, and “SECOND CODE NO.”.
• For setting and operation, refer to the “FIELD SETTING” in
the installation manual of the remote controller.
• Set the remote controller to the field set mode.
For details, refer to the “HOW TO SET IN THE FIELD”, in
the remote controller manual.
• When in the field set mode, select mode No. 12, then set
the first code (switch) No. to “1”. Then set second code
(position) No. to “01” for FORCED OFF and “02” for ON/
OFF OPERATION. (FORCED OFF at factory set)
12. TEST OPERATION
Refer to the installation manual of the outdoor unit.
•
The operation lamp of the remote controller will flash when
an malfunction occurs. Check the malfunction code on the
liquid crystal display to identify the point of trouble. An expla-
nation of malfunction codes and the corresponding trouble is
provided in “CAUTION FOR SERVICING” of the indoor unit.
If any of the items in Table 5 are displayed, there may be a
problem with the wiring or power, so check the wiring again.
Table 5
CLAMP MATERIAL
(accessory)
SETTING
Mode No.
SECOND
CODE NO.
FIRST CODE
NO.
FIELD SET
MODE
Remote control display
Content
“Concentrated Manage-
ment” is lit up
• There is a short circuit at the
FORCED OFF terminals (T1, T2).
“U4” is lit up
“UH” is lit up
• The power on the outdoor unit is off.
• The outdoor unit has not been wired
for power supply.
• Incorrect wiring for the transmission
wiring and / or FORCED OFF wiring.
No display
• The power on the indoor unit is off.
• The indoor unit has not been wired for
power supply.
• Incorrect wiring for the remote control-
ler wiring, the transmission wiring,
and / or the FORCED OFF wiring.