background image

 

Installation and operation manual

7

FXCQ20~125M8V3B

VRV System air conditioners

4PW25081-1A

I

NSTALLATION

 

OF

 

THE

 

DECORATION

 

PANEL

Refer to the installation manual attached to the decoration panel.

After installing the decoration panel, ensure that there is no space
between the unit body and decoration panel.

T

EST

 

OPERATION

Refer to the installation manual of the outdoor unit.

The operation lamp of the remote controller will flash when an
error occurs. Check the error code on the liquid crystal display to
identify the trouble. An explanation of error codes and the
corresponding trouble is provided on "Caution for servicing"
sticker on the indoor units switch box.

Precautions

In case something is wrong with the unit and it does not operate,
refer to the malfunction diagnosis label attached to the unit.

M

AINTENANCE

IMPORTANT

ONLY A QUALIFIED SERVICE PERSON IS ALLOWED TO
PERFORM MAINTENANCE.

BEFORE OBTAINING ACCESS TO TERMINAL DEVICES, ALL
POWER SUPPLY CIRCUITS MUST BE INTERRUPTED.

DO NOT USE WATER OR AIR OF 50°C OR HIGHER FOR
CLEANING AIR FILTERS AND OUTSIDE PANELS.

How to clean the air filter

Clean the air filter when the display shows "

" (TIME TO CLEAN

AIR FILTER).

Increase the frequency of cleaning if the unit is installed in a room
where the air is extremely contaminated.

(As a yardstick for yourself, consider cleaning the filter once a half
year.)

If dirt becomes impossible to clean, change the air filter. (Air filter for
exchange is optional.)

1.

Open the suction grille.
Grip the suction grille on one side, and open by pulling toward
yourself while holding it up.

2.

Remove the air filters.
Push the air filters operation section with both hands in the
direction indicated by the arrow, undo the air filter clips, and take
out downward.

3.

Clean the air filter.
Use a vacuum cleaner or wash the air filter with water.
When the air filter is very dirty, use a soft brush and neutral
detergent.

Remove water and dry in the shade.

1

Drain pumping device (built-in) drain water is removed from the 
room during cooling

2

Air flow flap (at air outlet)

3

Air outlet

4

Remote controller

5

Air inlet

6

Air filter (inside suction grille)

5  

6

4  

3  

2  

NOTE

Do not let go of the suction grille when opening or 
closing it. If released, the grille will spring back closed.

1

Clip

2

Operation section

3

Air filter

1

3

2

Содержание FXCQ125M8V3B

Страница 1: ...INSTALLATION AND OPERATION MANUAL FXCQ20M8V3B FXCQ25M8V3B FXCQ32M8V3B FXCQ40M8V3B FXCQ50M8V3B FXCQ63M8V3B FXCQ80M8V3B FXCQ125M8V3B System air conditioners...

Страница 2: ...680 20 20 20 20 C B 6 5 A D 2 7 1 2 3 4 7 2 6 5 2 3 4 5 1 100 1 2 3 4 1 3 6 4 5 2 1 3 4 5 2 1 2 300 mm 1 15 m 600 290 2 3 4 6 5 1 5 6 8 7 9 13 12 10 11 3 4 2 1 100 mm 1 1 7 5 6 2 3 4 P 1 P 2 F 1 F 2 T...

Страница 3: ...zgodnie z naszymi instrukcjami 18 sunt n conformitate cu urm torul urm toarele standard e sau alt e document e normativ e cu condi ia ca acestea s fie utilizate n conformitate cu instruc iunile noastr...

Страница 4: ...cessories are included with your unit Optional accessories There are two types of remote controllers wired and wireless Select a remote controller according to customers request and install in an appr...

Страница 5: ...ng Consult the builder for details 3 Install the suspension bolts use either a W3 8 or M10 size bolt Use anchors for existing ceilings and a sunken insert sunken anchors or other field supplied parts...

Страница 6: ...to a fire Finally make sure there is no refrigerant gas leak A toxic gas may be released by the refrigerant gas leaking indoor and being exposed to flames from an area heater cooking stove etc Table 1...

Страница 7: ...indoor unit as unit A unit B and be sure the terminal board wiring to the outdoor unit and BS unit are properly matched If wiring and piping between the outdoor unit and an indoor unit are mismatched...

Страница 8: ...ld damage the entire system 7 Use only specified wires and tightly connect wires to the terminals Be careful that wires do not place external stress on the terminals Keep wiring in neat order so that...

Страница 9: ...if installed See note 5 6 Use remote controller sensor only See note 5 6 3 Setting for display of time between 2 filter cleaning display indications Display Do not display 5 Information to I manager...

Страница 10: ...ILTERS AND OUTSIDE PANELS How to clean the air filter Clean the air filter when the display shows TIME TO CLEAN AIR FILTER Increase the frequency of cleaning if the unit is installed in a room where t...

Страница 11: ...e outdoor unit How to clean the air outlet and outside panels Clean with a soft cloth When it is difficult to remove stains use water or neutral detergent DISPOSAL REQUIREMENTS Dismantling of the unit...

Страница 12: ...N OFF BUTTON H1P LIGHT EMITTING DIODE ON RED H2P LIGHT EMITTING DIODE TIMER GREEN H3P LIGHT EMITTING DIODE FILTER SIGN RED H4P LIGHT EMITTING DIODE DEFROST ORANGE SS1 SELECTOR SWITCH MAIN SUB SS2 SELE...

Страница 13: ...P1 P2 F1 F2 T1 T2 1 2 3 4 IN D OUT D F1 F2 F1 F2 Control box IN D OUT D F1 F2 F1 F2 Control box L N P1 P2 LN P1 P2 F1 F2 T1 T2 1 3 6 2 L N IN D OUT D F1 F2 F1 F2 Control box LN P1 P2 P1 P2 F1 F2 T1 T...

Страница 14: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PW25081 1A...

Отзывы: