background image

DAIKIN HEAT PUMP 
CONVECTOR

OPERATION 
MANUAL

English

Deutsc

h

Français

Nederlands

Español

Italiano

ÅëëçíéêÜ

P

or

tugues

Nor

sk

Svenska

MODELS

FWXV15AVEB
FWXV20AVEB

00_CV_3P257979-1A.fm  Page 1  Tuesday, March 3, 2015  2:42 PM

Содержание FWXV15AVEB

Страница 1: ...DAIKIN HEAT PUMP CONVECTOR OPERATION MANUAL English Deutsch Français Nederlands Español Italiano ÅëëçíéêÜ Portugues Norsk Svenska MODELS FWXV15AVEB FWXV20AVEB ...

Страница 2: ...reparation before Operation 7 OPERATION COOL HEAT FAN Operation 10 Adjusting the Airflow Direction 12 POWERFUL Operation 14 FORCED QUIET Operation 15 OFF TIMER Operation 16 ON TIMER Operation 17 WEEKLY TIMER Operation 18 CARE Care and Cleaning 26 TROUBLESHOOTING Troubleshooting 30 ...

Страница 3: ...ch circumstances may result in a failure electric shocks or fire hazards Be sure to install an earth leakage breaker Failure to install an earth leakage breaker may result in electric shocks or fire This unit is designed for use with chilled or hot water Using steam may damage the unit or cause it to malfunction and can lead to a burning Be sure to earth the unit Do not earth the unit to a utility...

Страница 4: ...ter in the unit s water pipes Either fill the pipes with an anti freeze solution or discharge the water Leaving water in the pipes can cause water leakage Be sure to take an anti freeze measure to the unit not in use for a long period To avoid electric shocks do not operate with wet hands Do not wash the unit with water as this may result in electric shocks or fire Do not place water containers fl...

Страница 5: ...ker off Do not touch the metal parts on the inside of the indoor unit as it may result in injury 2 7 3 10 9 7 4 1 8 6 12 15 13 11 14 5 Air outlet selection switch This setting blows air from upper outlet only This setting automatically decides a blow pattern depending on mode and conditions This setting is recommended The unit is shipped from the factory with this setting ...

Страница 6: ...The louvers are inside of the air outlet page 12 10 Model name plate 11 Indoor unit ON OFF switch The operation mode will be the mode that was in effect before the unit was stopped This switch is useful when the remote controller is missing 12 OPERATION lamp green 13 TIMER lamp yellow page 16 14 Air outlet selection switch page 13 15 Signal receiver It receives signals from the remote controller W...

Страница 7: ...djustment buttons It changes the temperature setting 7 MODE selector button It selects the operation mode COOL HEAT FAN page 10 8 QUIET button FORCED QUIET operation page 15 9 SWING button Adjusting the airflow direction page 12 10 WEEKLY PROGRAM COPY BACK NEXT button WEEKLY TIMER operation page 18 11 SELECT button It changes the ON OFF TIMER and WEEKLY TIMER settings page 16 18 12 OFF TIMER butto...

Страница 8: ...replace both old batteries together When the system is not used for a long time take the batteries out The batteries will last for approx 1 year If the remote controller display begins to fade and the degradation of reception performance occurs within a year however replace both batteries with new size AAA LR03 alkaline The attached batteries are provided for the initial use of the system The usab...

Страница 9: ...es or decreases the time display 5 Press Always point the remote controller at the indoor unit when pushing the buttons when setting the indoor unit s internal clock blinks Turn the breaker on Turning on the breaker opens once and closes the flap This is a normal procedure NOTE Note on setting the clock If the indoor unit s internal clock is not set to the correct time the WEEKLY TIMER will not op...

Страница 10: ... to the following explanation and make the setting as shown in the illustration For customers of heating cooling use Set to H C For customers of heating only use Set to H O NOTE There is a risk of injury if you touch the heat exchanger with your bare hand Be sure to close the air purge valve after purging air Leaving the air purge valve open may result in water leakage and decreased performance Wa...

Страница 11: ...h the same operation mode To start operation 1 Press and select a operation mode Each pressing of the button advances the mode setting in sequence 2 Press is displayed on the LCD The OPERATION lamp lights up To stop operation 3 Press again disappears from the LCD Then OPERATION lamp goes off COOL HEAT FAN Heating only use Heating cooling use ...

Страница 12: ...oise quieter NOTE COOL or HEAT operation FAN operation Press to raise the temperature and press to lower the temperature The temperature setting is not variable Set to the temperature you like COOL or HEAT or FAN operation 5 levels of airflow rate setting from to plus are available Note on COOL and HEAT operation Use the unit within the following water temperature range Minimum water temperature 6...

Страница 13: ...ove the louvers You will find a knob on the left side and the right side blades NOTE Upper and lower airflow direction Note on flap and louvers angle Unless SWING is selected you should set the flap at a near horizontal angle in HEAT operation and at a upward position in COOL operation to obtain the best performance During COOL operation the range within which the flap swings differs from the rang...

Страница 14: ...fully cool or when one hour has passed since turning on the unit So that air does not come into direct contact with people air is blown upper air outlet room temperature is equalized At start of operation or other times when the room is not fully cooled Air is blown from the upper and lower air outlets for high speed cooling during COOL operation and for filling the room with warm air during HEAT ...

Страница 15: ...the LCD To cancel POWERFUL operation 2 Press again disappears from the LCD NOTE Notes on POWERFUL operation POWERFUL operation cannot be used together with FORCED QUIET operation Priority is given to the function of whichever button is pressed last POWERFUL operation can only be set when the unit is running In COOL and HEAT operation To maximize the cooling heating effect and the airflow rate be f...

Страница 16: ...QUIET operation 1 Press is displayed on the LCD To cancel FORCED QUIET operation 2 Press again disappears from the LCD NOTE Notes on FORCED QUIET operation POWERFUL operation and FORCED QUIET operation cannot be used at the same time Priority is given to the function of whichever button is pressed last Cooling and heating capacity may be slightly lower than during normal operation ...

Страница 17: ... increases or decreases the time setting by 10 minutes Holding down either button changes the setting rapidly 3 Press again The TIMER lamp lights up To cancel OFF TIMER operation 4 Press and setting time disappear from the LCD and day of the week are displayed on the LCD The TIMER lamp goes off NOTE Notes on TIMER operation When TIMER is set the present time is not displayed Once you set ON OFF TI...

Страница 18: ...n either button changes the setting rapidly 3 Press again The TIMER lamp lights up To cancel ON TIMER operation 4 Press and setting time disappear from the LCD and day of the week are displayed on the LCD The TIMER lamp goes off To combine ON TIMER and OFF TIMER A sample setting for combining the 2 timers is shown below NOTE In the following cases set the timer again After a breaker has turned off...

Страница 19: ...e copy mode ensures ease of making reservations The use of ON ON ON ON settings for example makes it possible to schedule operation mode and set temperature changes Furthermore by using OFF OFF OFF OFF settings only the turn off time of each day can be set This will turn off the unit automatically if the user forgets to turn it off Make timer settings up to programs 1 4 see page 19 Monday No timer...

Страница 20: ...r Pressing the changes the reservation number and the day of the week 3 Press The day of the week and reservation number will be set and blink 4 Press to select the desired mode Pressing the changes or setting in sequence In case the reservation has already been set selecting blank deletes the reservation Go to step 9 if blank is selected 5 Press The ON OFF TIMER mode will be set and the time blin...

Страница 21: ... at 30 C even if it is set at 31 to 32 C To return to the time setting press The set temperature is only displayed when the mode setting is on 9 Press The temperature will be set and go to the next reservation setting To continue further settings repeat the procedure from step 4 10 Press to complete the setting Be sure to direct the remote controller toward the indoor unit and check for a receivin...

Страница 22: ...ve The WEEKLY TIMER will go into standby state and will disappear from the LCD When ON OFF TIMER is up the WEEKLY TIMER will automatically become active Only the time and set temperature set with the weekly timer are sent with the Set the weekly timer only after setting the operation mode the fan strength and the fan direction ahead of time Shutting the breaker off power failure and other similar ...

Страница 23: ...day of the week to be copied 3 Press to activate copy mode The whole reservation of the selected day of the week will be copied 4 Press to select the destination day of the week Copy mode 6 00 8 30 17 30 22 00 25 C 27 C 6 00 8 30 17 30 22 00 25 C 27 C Program 1 Program 2 Program 3 Program 4 ON OFF ON OFF Monday Program 1 Program 2 Program 3 Program 4 ON OFF ON OFF Tuesday to Friday COPY ...

Страница 24: ...ress to complete the setting is displayed on the LCD and WEEKLY TIMER operation is activated NOTE Note on COPY MODE The entire reservation of the source day of the week is copied in the copy mode In the case of making a reservation change for any day of the week individually after copying the content of weekly reservations press and change the settings in the steps of setting mode page 19 Setting ...

Страница 25: ...ect the reservation number and press The mode is switched to setting mode Go to setting mode step 4 page 19 3 Press to exit confirming mode is displayed on the LCD and WEEKLY TIMER operation is activated The TIMER lamp lights up To deactivate WEEKLY TIMER operation 4 Press while is displayed on the LCD The will disappear from the LCD The TIMER lamp goes off To reactivate the WEEKLY TIMER operation...

Страница 26: ... 6 Select the day of the week to be canceled with 7 Hold for 5 seconds The reservation of the selected day of the week will be deleted 8 Hold for 5 seconds while normal display Be sure to direct the remote control toward the main unit and check for a receiving tone This operation is not effective while WEEKLY TIMER is being set All reservations will be deleted The individual reservation The reserv...

Страница 27: ...grooves of the unit 3 places Attach the string to the right inner side of the front grille Close the front panel slowly CAUTION CAUTION Before cleaning be sure to stop the operation and turn the breaker off Units Don t touch the metal parts of the indoor unit If you touch those parts this may cause an injury When removing or attaching the front panel use a robust and stable stool and watch your st...

Страница 28: ... in 4 places 3 Clean or replace each filter 3 1 Air filter 3 1 1 Wash the air filter with water or clean them with vacuum cleaner If the dust does not come off easily wash them with neutral detergent thinned with lukewarm water then dry them up in the shade Be sure to remove the titanium apatite photocatalytic air purifying filter It is recommended to clean the air filter every 2 weeks Filters Air...

Страница 29: ...me and replace with a new filter Do not throw away the filter frame Reuse the filter frame when replacing the titanium apatite photocatalytic air purifying filter Dispose of the old filter as non flammable waste 4 Set the air filter and titanium apatite photocatalytic air purifying filter as they were and close the front panel Operation without air filter may result in troubles as dust will accumu...

Страница 30: ...d set them again 4 Take out batteries from the remote controller In certain operating conditions the inside of the unit may get foul after several seasons of use resulting in poor performance It is recommended to have periodical maintenance by a specialist aside from regular cleaning by the user For specialist maintenance contact the service shop where you bought the unit The maintenance cost must...

Страница 31: ...wing This is a pumping sound of the water in the unit and heard when the water is pumped out from the unit in COOL operation The water flows in the unit even if the unit is not working when the indoor units in other rooms are in operation Pinging sound This sound is generated when the size of the unit slightly expands or shrinks as a result of temperature changes The unit does not operate OPERATIO...

Страница 32: ...windows and doors closed Are the airflow rate and the airflow direction set appropriately Chilled or hot water is not circulating Remote controller does not work properly No remote controller signals are displayed The remote controller sensitivity is low The display is low in contrast or blacked out The display runs out of control The batteries are dying and the remote controller is malfunctioning...

Страница 33: ...This happens when smells of the room furniture or cigarettes are absorbed into the unit and discharged with the airflow If this happens we recommend you to have the indoor unit washed by a technician Consult the service shop where you bought the unit An abnormal functioning happens during operation The unit may malfunction with lightning or radio waves Turn the breaker off turn it on again and try...

Страница 34: ...b lead 0 004 Do not try to dismantle the system yourself the dismantling of the product and of other parts must be done by a qualified installer in accordance with relevant local and national legislation Units and waste batteries must be treated at a specialized treatment facility for re use recycling and recovery By ensuring correct disposal you will help to prevent potential negative consequence...

Страница 35: ...ntinuous beep is produced The code indication changes as shown below and notifies with a long beep NOTE Fault diagnosis CODE MEANING 00 NORMAL A1 INDOOR PCB DEFECTIVENESS A6 FAN MOTOR FAULT C4 FAULTY HEAT EXCHANGER TEMPERATURE SENSOR C9 FAULTY SUCTION AIR TEMPERATURE SENSOR A short beep and 2 consecutive beeps indicate non corresponding codes To cancel the code display hold the down for 5 seconds ...

Страница 36: ... 1503 HT 3P257979 1A M09B168A The two dimensional bar code is a manufacturing code ...

Отзывы: