manualshive.com logo in svg
background image

MODELS
FVXS25FV1A

FVXS50FV1A

FVXS35FV1A

DAIKIN ROOM AIR CONDITIONER

Operation Manual

00_CV_3P191290-2K.fm  Page 1  Thursday, March 26, 2009  9:42 AM

Содержание FVXS25FV1A

Страница 1: ...MODELS FVXS25FV1A FVXS50FV1A FVXS35FV1A DAIKIN ROOM AIR CONDITIONER Operation Manual 00_CV_3P191290 2K fm Page 1 Thursday March 26 2009 9 42 AM...

Страница 2: ...L HEAT FAN Operation 10 Adjusting the Airflow Direction 12 POWERFUL Operation 14 OUTDOOR UNIT QUIET Operation 15 ECONO Operation 16 TIMER Operation 17 WEEKLY TIMER Operation 19 Note for Multi System 2...

Страница 3: ...accompanying adding refrigerant check the content of the repairs with our service staff Do not attempt to install the air conditioner by your self Incorrect work will result in water leakage electric...

Страница 4: ...around the unit Leaves are a hotbed for small animals which can enter the unit Once in the unit such animals can cause malfunctions smoke or fire when making contact with electrical parts Do not opera...

Страница 5: ...al parts on the inside of the indoor unit as it may result in injury 1 2 6 5 2 4 7 8 3 9 12 10 11 13 14 Air outlet selection switch This setting blows air from upper outlet only This setting automatic...

Страница 6: ...tch is useful when the remote controller is missing 12 Signal receiver It receives signals from the remote controller When the unit receives a signal you will hear a short beep Operation start beep be...

Страница 7: ...ector button It selects the operation mode AUTO DRY COOL HEAT FAN page 10 8 QUIET button OUTDOOR UNIT QUIET operation page 15 9 ECONO button ECONO operation page 16 10 SWING button Adjusting the Airfl...

Страница 8: ...system is not used for a long time take the batteries out We recommend replacing once a year although if the remote controller display begins to fade or if reception deteriorates please replace with...

Страница 9: ...present time Holding down or button rapidly increases or decreases the time display 5 Press CLOCK button Always point the remote controller at the indoor unit when pushing the buttons when setting the...

Страница 10: ...ure range may cause a safety device to disable the system Recommended temperature setting For cooling 26 C 28 C For heating 20 C 24 C Mode Operating conditions If operation is continued out of this ra...

Страница 11: ...ances the mode setting in sequence AUTO DRY COOL HEAT FAN 2 Press ON OFF button The OPERATION lamp lights up To stop operation 3 Press ON OFF button again Then OPERATION lamp goes off To change the te...

Страница 12: ...e outdoor unit and lower the heating capacity In that case the system switches into defrosting operation to take away the frost During defrosting operation hot air does not flow out of indoor unit Not...

Страница 13: ...Hold the knob and move the louver You will find a knob on the left side and the right side blades Notes on flap and louvers angle Unless SWING is selected you should set the flap at a near horizontal...

Страница 14: ...de When the room has become fully cool or when one hour has passed since turning on the air conditioner So that air does not come into direct contact with people air is blown upper air outlet room tem...

Страница 15: ...on of whichever button is pressed last POWERFUL Operation can only be set when the unit is running Pressing the operation stop button causes the settings to be canceled and the disappears from the LCD...

Страница 16: ...l operated indoor units However if using priority room setting see Note for Multi System page 24 This function is available in COOL HEAT and AUTO modes This is not available in FAN and DRY mode POWERF...

Страница 17: ...O Operation can only be set when the unit is running Pressing the operation stop button causes the settings to be canceled and the disappears from the LCD ECONO operation is a function which enables e...

Страница 18: ...ly 3 Press OFF TIMER button again The TIMER lamp lights up To cancel the OFF TIMER Operation 4 Press CANCEL button The TIMER lamp goes off NOTE When TIMER is set the present time is not displayed Once...

Страница 19: ...ng rapidly 3 Press ON TIMER button again The TIMER lamp lights up To cancel ON TIMER operation 4 Press CANCEL button The TIMER lamp goes off To combine ON TIMER and OFF TIMER A sample setting for comb...

Страница 20: ...f ON ON ON ON settings for example makes it possible to schedule operating mode and set temperature changes Furthermore by using OFF OFF OFF OFF settings only the turn OFF time of each day can be set...

Страница 21: ...button changes or setting in sequence In case the reservation has already been set selecting blank deletes the reservation Go to STEP 9 if blank is selected 5 Press NEXT button The ON OFF TIMER mode...

Страница 22: ...forget to set the clock on the remote control first The day of the week ON OFF TIMER mode time and set temperature only for ON TIMER mode can be set with WEEKLY TIMER Other settings for ON TIMER are b...

Страница 23: ...days of the week repeat STEP 4 and STEP 5 6 Press button to complete the setting is displayed on the LCD and WEEKLY TIMER operation is activated NOTE Copy mode COPY MODE The entire reservation of the...

Страница 24: ...n again If a reservation deactivated with WEEKLY button is activated once again the last reservation mode will be used To delete reservations Refer to page 20 When selecting desired mode at STEP 4 in...

Страница 25: ...retailer or dealer for assistance NIGHT QUIET Mode reduces the operation noise of the outdoor unit during the night time hours to prevent annoyance to neighbors The NIGHT QUIET Mode is activated when...

Страница 26: ...POWERFUL operation operation capacity will be concentrated in Room A In such a case the cooling heating efficiency of the units in Rooms B C and D may be slightly reduced 3 Priority when using OUTDOOR...

Страница 27: ...nit 3 places Attach the string to the right inner side of the front grille Close the panel slowly CAUTION Units Don t touch the metal parts of the indoor unit If you touch those parts this may cause a...

Страница 28: ...ukewarm water then dry them up in the shade It is recommended to clean the air filters every 2 weeks Titanium Apatite Photocatalytic Air Purifying Filter The Titanium Apatite Photocatalytic Air Purify...

Страница 29: ...hop there you bought the air conditioner Dispose of old filters as flammable waste Check that the base stand and other fittings of the outdoor unit are not decayed or corroded Check that nothing block...

Страница 30: ...oor unit gives out odour This happens when smells of the room furniture or cigarettes are absorbed into the unit and discharged with the airflow If this happens we recommend you to have the indoor uni...

Страница 31: ...air filters or take all obstacles away and turn the breaker OFF Then turn it ON again and try operating the air conditioner with the remote controller If the lamp still flashes call the service shop w...

Страница 32: ...ce by a specialist aside from regular cleaning by the user For specialist maintenance contact the service shop where you bought the air conditioner The maintenance cost must be born by the user Call t...

Страница 33: ...32 MEMO 01_EN_3P191290 2K fm Page 32 Saturday March 28 2009 12 02 PM...

Страница 34: ...0904 HT 3P191290 2K M06B130C Two dimensional bar code is a code for manufacturing 00_CV_3P191290 2K fm Page 2 Thursday March 26 2009 9 42 AM...

Отзывы: