background image

2

READ BEFORE OPERATION

Safety precautions

• Keep this manual where the operator can easily find them.
• Read this manual attentively before starting up the unit.
• For safety reason the operator must read the following cautions carefully.
• This manual classifies precautions into WARNINGS and CAUTIONS. Be sure to follow all precautions below: they are 

all important for ensuring safety.

WARNING

• In order to avoid fire, explosion or injury, do not operate the unit when harmful, among which flammable or 

corrosive gases, are detected near the unit.

• It is not good for health to expose your body to the air flow for a long time.
• Do not put a finger, a rod or other objects into the air outlet or inlet. As the fan is rotating at a high speed, it will 

cause injury.

• Do not attempt to repair, relocate, modify or reinstall the air conditioner by yourself. Incorrect work will cause electric 

shocks, fire etc. 
For repairs and reinstallation, consult your Daikin dealer for advice and information.

• The refrigerant used in the air conditioner is safe. Although leaks should not occur, if for some 

reason any refrigerant happens to leak into the room, make sure it does not come in contact 
with any flame as of gas heaters, kerosene heaters or gas range.

• If the air conditioner is not cooling (heating) properly, the refrigerant may be leaking, so call your dealer.

When carrying out repairs accompanying adding refrigerant, check the content of the repairs with our service staff.

• Do not attempt to install the air conditioner by your self. Incorrect work will result in water leakage, electric shocks or 

fire. For installation, consult the dealer or a qualified technician.

• In order to avoid electric shock, fire or injury, if you detect any abnormally such as smell of fire, stop the operation and 

turn off the breaker. And call your dealer for instructions.

CAUTION

• The air conditioner must be earthed. Incomplete earthing may result in electric shocks. Do not connect the 

earth line to a gas pipe, water pipe, lightening rod, or a telephone earth line.

• In order to avoid any quality deterioration, do not use the unit for cooling precision instruments, food, plants, 

animals or works of art.

• Never expose little children, plants or animals directly to the air flow.
• Do not place appliances which produce open fire in places exposed to the air flow from the unit or under the 

indoor unit. It may cause incomplete combustion or deformation of the unit due to the heat.

• Do not block air inlets nor outlets. Impaired air flow may result in insufficient performance or trouble.

WARNING

If you do not follow these instructions exactly, the unit may 
cause property damage, personal injury or loss of life.

CAUTION

If you do not follow these instructions exactly, the unit may 
cause minor or moderate property damage or personal injury.

Never do.

Be sure to follow the instructions.

Be sure to earth the air conditioner.

Never cause the air conditioner (including the remote 

controller) to get wet.

Never touch the air conditioner (including the remote 

controller) with a wet hand.

01_EN_3P098587-1_1.book  Page 2  Thursday, December 5, 2002  6:01 PM

Содержание FVXS25BVMB

Страница 1: ...ederlands Espa ol Italiano Portugues Russian MODELS DAIKIN ROOM AIR CONDITIONER Operation Manual FVXS25BVMB FVKS25BVMB FVXS35BVMB FVKS35BVMB FVXS50BVMB FVKS50BVMB 00_CV_3P098587 1_1 fm Page 1 Wednesda...

Страница 2: ...0212 HT 3P098587 1 M02B053 00_CV_3P098587 1_1 fm Page 2 Wednesday October 23 2002 4 15 PM...

Страница 3: ...DRY COOL HEAT FAN Operation 10 Adjusting the Air Flow Direction 12 POWERFUL Operation 14 OUTDOOR UNIT SILENT Operation 15 HOME LEAVE Operation 16 TIMER Operation 18 Note for Multi System 20 CARE Care...

Страница 4: ...staff Do not attempt to install the air conditioner by your self Incorrect work will result in water leakage electric shocks or fire For installation consult the dealer or a qualified technician In o...

Страница 5: ...it with excessive water only use a slightly wet cloth Do not place things such as vessels containing water or anything else on top of the unit Water may pene trate into the unit and degrade electrical...

Страница 6: ...ide of the indoor unit as it may result in injury ON OFF 1 2 4 5 2 6 7 8 3 9 11 10 14 15 12 13 Air outlet selection switch This setting blows air from upper outlet only This setting automatically deci...

Страница 7: ...table This switch is useful when the remote controller is missing 13 Signal receiver Signals are received from the remote controller When the unit receives a signal you will hear a short beep Operati...

Страница 8: ...operation Press once again to stop it 7 MODE selector button It selects the operation mode AUTO DRY COOL HEAT FAN page 10 8 SILENT button for OUTDOOR UNIT SILENT operation page 15 9 FAN setting butto...

Страница 9: ...ot used for a long time take the batteries out We recommend replacing once a year although if the remote controller display begins to fade or if reception deteriorates please replace with new alkali b...

Страница 10: ...h the screws supplied with the holder 3 Place the remote controller in the remote controller holder ATTENTION About remote controller Never expose the remote controller to direct sunlight Dust on the...

Страница 11: ...umn turn the breaker OFF Use the air conditioner in the following conditions Operation outside this humidity or temperature range may cause a safety device to disable the system C TEMP ON OFF POWERFUL...

Страница 12: ...EAT FAN 2 Press ON OFF button The OPERATION lamp lights up To stop operation 3 Press ON OFF button again Then OPERATION lamp goes off To change the temperature setting 4 Press TEMPERATURE adjustment b...

Страница 13: ...and lower the heating capacity In that case the system switches into defrosting operation to take away the frost During defrosting operation hot air does not flow out of indoor unit At the start of he...

Страница 14: ...will find a knob on the left side and the right side blades Notes on flap and louvers angle Unless SWING is selected you should set the flap at a near horizontal angle in HEAT mode and at a upward po...

Страница 15: ...de When the room has become fully cool or when one hour has passed since turning on the air conditioner So that air does not come into direct contact with people air is blown upper air outlet room tem...

Страница 16: ...s POWERFUL button again NOTE Notes on POWERFUL operation In COOL and HEAT mode To maximize the cooling heating effect the capacity of outdoor unit must be increased and the air flow rate be fixed to t...

Страница 17: ...ENT operation is set on all operated indoor units However if using priority room setting see Note for multi system page 20 This function is available in COOL HEAT and AUTO modes This is not available...

Страница 18: ...E operation Record your preferred temperature and air flow rate 1 Press HOME LEAVE button Make sure is displayed in the remote control ler display 2 Adjust the set temperature with or as you like 3 Ad...

Страница 19: ...ush the HOME LEAVE Operation button again and the air conditioner will adjust capacity to the set tem perature for normal operation Set the unit to HOME LEAVE Opera tion before leaving the living room...

Страница 20: ...IMER lamp lights up To cancel the OFF TIMER Operation 4 Press CANCEL button The TIMER lamp goes off Notes When TIMER is set the present time is not displayed Once you set ON OFF TIMER the time setting...

Страница 21: ...MER lamp lights up To cancel ON TIMER operation 4 Press CANCEL button The TIMER lamp goes off To combine ON TIMER and OFF TIMER A sample setting for combining the two timers is shown below ATTENTION I...

Страница 22: ...onsult your retailer or dealer for assistance NIGHT QUIET Mode reduces the operation noise of the outdoor unit during the night time hours to prevent annoyance to neighbors The NIGHT QUIET Mode is act...

Страница 23: ...RFUL operation operation capacity will be concentrated in Room A In such a case the cooling heating efficiency of the units in Rooms B C and D may be slightly reduced 3 Priority when using OUTDOOR UNI...

Страница 24: ...inner side of the front grille Close the grille slowly CAUTION Units Hold the front grille firmly so that it does not fall Do not touch the metal parts on the inside of the indoor unit as it may resu...

Страница 25: ...hade It is recommended to clean the air filters every two weeks Air Purifying Filter green Replace approximately once every 3 months 1 Detach the filter element and attach a new one Insert with the gr...

Страница 26: ...wers the cooling heating capacity and wastes energy Air is also prevented from flowing smoothly through the unit creating a noise Operation with dirty filters 1 cannot deodorize the air 2 cannot clean...

Страница 27: ...In COOL or DRY mode Moisture in the air condenses into water on the cool surface of outdoor unit piping and drips Mists come out of the indoor unit This happens when the air in the room is cooled int...

Страница 28: ...r filters or take all obstacles away and turn the breaker OFF Then turn it ON again and try operating the air conditioner with the remote controller If the lamp still flashes call the service shop whe...

Страница 29: ...sons of use resulting in poor performance It is recommended to have periodical maintenance by a specialist aside from regular cleaning by the user For specialist maintenance contact the service shop w...

Страница 30: ...OR UNIT EA COOLING HEATING SWITCHING ERROR E5 OL STARTED E6 FAULTY COMPRESSOR START UP E7 DC FAN MOTOR FAULT E8 OPERATION HALT DUE TO DETECTION OF INPUT OVER CURRENT F3 HIGH TEMPERATURE DISCHARGE PIPE...

Страница 31: ...PROTECTOR WORKED OR FREEZE UP IN OPERATING UNIT OR STAND BY UNIT OVERLOAD RELAY WORKED OR HIGH DISCHARGE PIPE TEMPERATURE FAULTY COMPRESSOR START INPUT OVERCURRENT THERMISTOR OR CT ABNORMALITY HIGH TE...

Страница 32: ...30 MEMO 01_EN_3P098587 1_1 book Page 30 Thursday December 5 2002 6 01 PM...