Si06-763
Removal of the Fan Rotor / Fan Motor
Removal Procedure
13
6. Removal of the Fan Rotor / Fan Motor
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1
For removal of the
drain pan, disconnect
the drain hose, then
loosen the 2 screws
located at left and right
sides.
Be careful not to wet the
floor with drain water.
Disengage harness for drain
pan from right side hook.
2
Remove the drain pan.
This swing motor is for down
flow shutter.
3
To remove the swing
motor on discharge
port of the drain pan,
loosen the 2 fixing
screws.
(R2637)
(R2638)
Distributing louver
(R2639)