background image

9

English

HOW TO CLEAN THE AIR FILTER

When the remote controller indicates "

" or "Time to 

clean filter", clean the air filter.

It indicates after running for a certain time.

NOTE 

You may change the time of indication "

" or 

"Time to clean filter".

If the indoor unit is used in a space where the air is 
more contaminated, ask your local dealer for 
solution.

If it becomes difficult to remove contamination 
from the air filter, replace the air filter. 
(Air filter for replacement is an optional 
accessory)

1. Open the suction grille.

Simultaneously slide the two knobs, slowly down the 
suction grille.

2. Take out the air filter.

Carry out the work in the order mentioned below.

1

Pull the air filter end inclined downward and 
unhook the hooking hole of the air filter from 
the projection of the grille. (both right and left)

2

Lift the air filter and unhook the hooking hole 
of the air filter from the projection at the grille 
upper part. (both left and right)

Contamination

Time until indication is displayed

Normal

2500 hours
(equivalent to one year)

More contaminated

1250 hours
(equivalent to a half year)

a

knob

a

Grille upper part projection

b

Filter

c

Projection

d

Air filter end

a

a

2

1

2

1

1

2

a

b

b

b

c

d

3. Clean the filter.

Clean the contamination with a vacuum cleaner 
or wash it with water.

NOTE 

• Do not wash the air filter with water of 50°C or 

higher. 
It may cause decolorization and deformation. 

• Do not heat the filter with fire. 

It may cause burning.

4. Attach the air filter. 

Attach the air filter in the reverse order 
mentioned in step 2.

5. Close the suction grille.

Simultaneously slide the two knobs, slowly lift 
the suction grille and securely fix it in the reverse 
order mentioned in step 1.

6. Turn off the indication "

" or "Time to 

clean filter" displayed on the remote 
controller after turning on the power. 

For details, refer to the operation manual 
attached to the remote controller.
The indication can be turned off whether in 
operation or at stop.

NOTE 

When closing the suction grille, the strap is likely 
to be sandwiched.

Before closing the suction grille, confirm if the 
strap is not sticking out from the side of the 
suction grille.

If the air filter is 
extremely 
contaminated, 
wash it with 
neutral detergent 
using a soft brush.

After dewatering, 
dry the air filter in 
the shade.

a

Strap

b

Suction grille

a

b

4PEN465543-1.book  Page 9  Tuesday, March 14, 2017  3:08 PM

Содержание FUA100AVEB

Страница 1: ...OPERATION MANUAL FUA71AVEB FUA100AVEB FUA125AVEB Split system air conditioners...

Страница 2: ...se by lay persons This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have b...

Страница 3: ...tility piping lightning conductor or telephone earth lead Imperfect earthing may result in electric shocks or a fire A high surge current from lightning or other sources may cause damage to the air co...

Страница 4: ...e In the event of a gas leakage build up of gas near the air conditioner may result in a fire Carry out drain piping properly to ensure complete drainage If drain piping is not carried out properly dr...

Страница 5: ...roller 2 Unit without remote controller when used as simulta neous operation B OUTDOOR INDOOR 1 1 NOTE Contact your local dealer in case of changing the combination or setting of group control and two...

Страница 6: ...e there are machines generating electromagnetic waves h Filled with acid and or alkaline steam or vapor Is a snow protection measure taken For details consult your local dealer about snow protection h...

Страница 7: ...set The airflow direction becomes horizontal to prevent a draft of cool air to the inhabitants The remote controller displays the set airflow direction that is set DEFROST OPERATION Frost removal ope...

Страница 8: ...ller to set the airflow direction For details refer to the operation manual attached to the remote controller The horizontal blades at the air outlet are closed while the indoor unit stops AIRFLOW DIR...

Страница 9: ...outdoor unit is not in operation depends on the model 2 The setting before the power circuit breaker is cut off is stored The timer setting is cleared Fully use the function of airflow direction adju...

Страница 10: ...50 hours equivalent to a half year a knob a Grille upper part projection b Filter c Projection d Air filter end a a 2 1 2 1 1 2 a b b b c d 3 Clean the filter Clean the contamination with a vacuum cle...

Страница 11: ...ot wash the suction grille with warm water of 50 C or higher It may cause discoloration and deformation When drying the suction grille do not heat it with fire It may cause burning Do not use such as...

Страница 12: ...cuit breaker during seasonal use of the HEATING OPERATION WHAT TO DO WHEN STOPPING THE AIR CONDITIONER FOR A LONG PERIOD Turn on FAN OPERATION for a half day on the fine day and dry the indoor unit Th...

Страница 13: ...ndoor unit is in the FAN OPERATION COOLING OPERATION AUTOMATIC COOLING OPERATION Lower the set temperature HEATING OPERATION AUTOMATIC HEATING OPERATION Raise the set temperature The operation starts...

Страница 14: ...while the horizontal blades close VI WHITE MIST COMES OUT OF THE AIR CONDITIONER When humidity is high during the COOLING OPERATION In oily or dusty places If the inside of an indoor unit is extremely...

Страница 15: ...he power supply Check if the power circuit breaker is blown If the tab of power circuit breaker is in the OFF position turn the power on with the power circuit breaker switch If the tab of power circu...

Страница 16: ...following malfunctions occurs take the measures shown below and contact your local dealer The air conditioner must be repaired by a qualified service person WARNING When the air conditioner is malfun...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...4P465543 1 2017 01 Copyright 2017 Daikin...

Отзывы: