manualshive.com logo in svg
background image

 

變頻式空調

OPERATION MANUAL

使用說明書

MODELS  

型號

FTXV22XVLT
FTXV28XVLT
FTXV36XVLT
FTXV41XVLT
FTXV50XVLT
FTXV60XVLT
FTXV71XVLT
FTXV80XVLT
FTXV90XVLT

DAIKIN ROOM AIR CONDITIONER

DAIKIN 

空調機

中文 (繁體)

English

00_CV_3P697657-1.indd   1

31-Oct-22   2:57:17 PM

Содержание FTXV22XVLT

Страница 1: ...TION MANUAL MODELS FTXV22XVLT FTXV28XVLT FTXV36XVLT FTXV41XVLT FTXV50XVLT FTXV60XVLT FTXV71XVLT FTXV80XVLT FTXV90XVLT DAIKIN ROOM AIR CONDITIONER DAIKIN English 00_CV_3P697657 1 indd 1 31 Oct 22 2 57...

Страница 2: ...rhood Page 21 INTELLIGENT EYE The INTELLIGENT EYE sensor detects human movement in a room If no one is in the room for more than 20 minutes the operation automatically changes to energy saving operati...

Страница 3: ...ore Operation 9 Basic Operation AUTO DRY COOL HEAT FAN ONLY Operation 10 Adjusting the Airflow Rate 12 Adjusting the Airflow Direction 13 Useful Functions MOLD PROOF Operation 14 FLASH STREAMER AIR CL...

Страница 4: ...conditioner s high speed fan blades Do not attempt to repair dismantle reinstall or modify the air conditioner yourself as this may result in water leakage electric shock or fire hazards Do not use f...

Страница 5: ...ou may topple over or injury yourself Locate the remote controller in places out of reach of children The wrong operation of the remote controller may result in injury To avoid oxygen depletion ensure...

Страница 6: ...oor unit ON OFF switch and OPERATION lamp Green Press this switch once to start operation Press once again to stop it For the operation mode setting refer to the following table Mode Temperature setti...

Страница 7: ...ackside of the front panel Fixing tab Panel support plate Outdoor temperature sensor back Earth terminal inside Refrigerant pipes and inter unit wire Drain hose Deodorizing filter enzyme blue Streamer...

Страница 8: ...el Fixing tab Panel support plate Outdoor temperature sensor back Refrigerant pipes and inter unit wire Drain hose Deodorizing filter enzyme blue Streamer unit inside Prevents mold and allergens with...

Страница 9: ...EL button Cancels the timer setting Page 22 23 Model name ARC480A80 Display LCD Displays the current settings In this illustration each section is shown with its displays on for the purpose of explana...

Страница 10: ...s accelerated owing usage conditions signal reception may decline before the LCD begins blinking The batteries supplied with the remote controller are for initial operation The batteries may run out i...

Страница 11: ...ct is insufficient it is recommended to use another heating appliance in combination with the air conditioner The heat pump system heats the room by circulating hot air around all parts of the room Af...

Страница 12: ...ise the temperature and press to lower the temperature Each pressing of the button changes the temperature by 0 5 C COOL operation HEAT operation AUTO operation DRY FAN ONLY operation 18 0 32 0 C 10 0...

Страница 13: ...s a small amount of electricity even while it is not operating Adjusting the Airflow Rate You can adjust the airflow rate to increase your comfort To adjust the airflow rate setting Press Each pressin...

Страница 14: ...d appear on the LCD The flaps and louvres move in turn To cancel 3 D airflow press either or again The flaps or louvres will stop moving To set the flaps or louvres at the desired position This functi...

Страница 15: ...unit is turned off using the OFF TIMER MOLD PROOF operation is a function which reduces the spread of mold by using FAN operation to lower the humidity inside the indoor unit To automatically operati...

Страница 16: ...r discharge This is a type of plasma discharge comprising high speed electrons with a high oxidative capacity that is released within the unit It decomposes odours and harmful gases The high speed ele...

Страница 17: ...up COMFORT AIRFLOW Operation The flow of air will be in the upward direction while in COOL DRY operation and in the downward direction while in HEAT operation which will provide a comfortable wind th...

Страница 18: ...place large objects near the INTELLIGENT EYE sensor Also keep heating units and humidifiers outside the sensor s detection area This sensor can detect undesirable objects Do not hit or violently push...

Страница 19: ...peration decreases the airflow rate slightly in FAN operation only NOTE Notes on INTELLIGENT EYE operation Application range is as follows 90 55 7m 55 Vertical angle 90 Side view Horizontal angle 110...

Страница 20: ...the capacity of the air conditioner if the air conditioner is already in operation with its maximum capacity demonstrated In COOL HEAT and AUTO operation To maximise the cooling heating effect the ca...

Страница 21: ...TE Notes on ECONO operation This operation is performed with lower power and therefore may not provide a sufficient cooling heating effect Pressing causes the settings to be cancelled and disappears f...

Страница 22: ...ation cannot be used at the same time Priority is given to the function of whichever button is pressed last Even the operation is stopped by using the remote controller or the indoor unit ON OFF switc...

Страница 23: ...set Press appears on the LCD Each pressing of changes the time setting by 1 hour The time can be set between 1 and 12 hours The TIMER lamp lights orange Display To cancel Press disappears from the LCD...

Страница 24: ...ting by 1 hour The time can be set between 1 and 12 hours The TIMER lamp lights orange Display To cancel Press disappears from the LCD The TIMER lamp goes off ON OFF TIMER combination To combine A sam...

Страница 25: ...lity filter enzyme blue with PM2 5 without frame BAFP094A43 set of 2 BAFP094A47 set of 3 Deodorizing filter enzyme blue without frame BAFP094A41 set of 2 BAFP094A45 set of 3 Dust collection filter PM...

Страница 26: ...t is recommended to clean the air filters every 2 weeks If the dust does not come off easily Wash the air filters with neutral detergent thinned with lukewarm water then dry them up in the shade Be su...

Страница 27: ...ilter can be renewed by washing it with water once every 6 months and we recommend replacing it once every 3 years Do not wiring out the filter when removing water from it Air quality filter enzyme bl...

Страница 28: ...ler We recommend periodical maintenance In certain operating conditions the inside of the air conditioner may get foul after several seasons of use resulting in poor performance It is recommended to h...

Страница 29: ...nt control valves or the electrical parts operate Clopping sound This sound is heard from the inside of the air conditioner when the exhaust fan is activated while the room doors are closed Open the w...

Страница 30: ...m up Case Description what to check Air does not come out In HEAT operation The air conditioner is warming up Wait for about 1 to 4 minutes During defrosting operation hot air does not flow out of the...

Страница 31: ...OFF button remains functional Other electric devices start operating If the remote controller activates other electric devices move them away or consult your dealer Air has an odour Case Description w...

Страница 32: ...breaker a fuse or the earth leakage circuit breaker cuts off the operation frequently A switch or a button often fails to work properly There is a burning smell Water leaks from the indoor unit Turn...

Страница 33: ...TURE SENSOR C9 FAULTY SUCTION AIR TEMPERATURE SENSOR CC FAULTY HUMIDITY SENSOR OUTDOOR UNIT EA COOLING HEATING SWITCHING ERROR E1 CIRCUIT BOARD FAULT E5 OL STARTED E6 FAULTY COMPRESSOR START UP E7 DC...

Страница 34: ...1 16 21 20 17 15 14 02_TW_3P697657 1 indd 1 30 Nov 22 3 44 48 PM...

Страница 35: ...2 20 3 5 9 10 12 13 14 15 16 17 19 20 21 22 24 FAQ 28 29 33 02_TW_3P697657 1 indd 2 30 Nov 22 3 44 50 PM...

Страница 36: ...3 R32 m2 FTXV22 28 36 1 9m2 FTXV41 50 2 5m2 FTXV60 3 5m2 FTXV71 6 2m2 FTXV80 90 1 22 1 8m R32 02_TW_3P697657 1 indd 3 30 Nov 22 3 44 51 PM...

Страница 37: ...4 1m 1m 02_TW_3P697657 1 indd 4 30 Nov 22 3 44 52 PM...

Страница 38: ...5 13 13 17 18 25 0 22 23 14 15 LAN LAN LAN BRP084C45 15 14 22 23 02_TW_3P697657 1 indd 5 30 Nov 22 3 44 52 PM...

Страница 39: ...6 15 FTXV22 28 36 41 50 60 71 02_TW_3P697657 1 indd 6 30 Nov 22 3 44 53 PM...

Страница 40: ...7 15 FTXV80 90 02_TW_3P697657 1 indd 7 30 Nov 22 3 44 54 PM...

Страница 41: ...8 ARC480A80 LCD 10 10 11 17 21 19 15 23 22 7m 7m 10 12 20 13 14 16 20 23 02_TW_3P697657 1 indd 8 30 Nov 22 3 44 55 PM...

Страница 42: ...9 1 AAA LR03 LCD LCD 1 1 2 AAA LR03 2 3 1 2 3 26 02_TW_3P697657 1 indd 9 30 Nov 22 3 44 59 PM...

Страница 43: ...10 LCD LCD LCD LCD LCD 02_TW_3P697657 1 indd 10 30 Nov 22 3 45 02 PM...

Страница 44: ...11 0 5 18 0 32 0 10 0 30 0 18 0 30 0 02_TW_3P697657 1 indd 11 30 Nov 22 3 45 02 PM...

Страница 45: ...12 26 0 28 0 20 0 24 0 2 25 1 5 1 02_TW_3P697657 1 indd 12 30 Nov 22 3 45 03 PM...

Страница 46: ...13 LCD LCD 3D LCD 3D 3D LCD 3D 3D 02_TW_3P697657 1 indd 13 30 Nov 22 3 45 06 PM...

Страница 47: ...14 2 LCD 2 LCD 2 LCD 60 02_TW_3P697657 1 indd 14 30 Nov 22 3 45 07 PM...

Страница 48: ...15 LCD LCD 1 1 02_TW_3P697657 1 indd 15 30 Nov 22 3 45 09 PM...

Страница 49: ...16 LCD LCD 02_TW_3P697657 1 indd 16 30 Nov 22 3 45 10 PM...

Страница 50: ...17 20 LCD LCD 02_TW_3P697657 1 indd 17 30 Nov 22 3 45 12 PM...

Страница 51: ...18 20 20 2 2 2 30 1 1 90 55 7m 55 90 110 7m 7m 23 02_TW_3P697657 1 indd 18 30 Nov 22 3 45 13 PM...

Страница 52: ...19 LCD 20 LCD LCD 2 5 02_TW_3P697657 1 indd 19 30 Nov 22 3 45 14 PM...

Страница 53: ...20 LCD LCD LCD 02_TW_3P697657 1 indd 20 30 Nov 22 3 45 15 PM...

Страница 54: ...21 LCD LCD 02_TW_3P697657 1 indd 21 30 Nov 22 3 45 16 PM...

Страница 55: ...22 LCD 1 1 12 LCD 02_TW_3P697657 1 indd 22 30 Nov 22 3 45 17 PM...

Страница 56: ...23 0 5 2 LCD 1 1 12 LCD LCD 1 7 2 3 02_TW_3P697657 1 indd 23 30 Nov 22 3 45 19 PM...

Страница 57: ...22 28 36 41 50 60 71 FTXV80 90 PM2 5 BAFP094A43 2 BAFP094A47 3 BAFP094A41 2 BAFP094A45 3 PM 2 5 BAFP046A41 2 BAFP046A43 3 KAF970A46 2 KAF970A48 3 6 3 26 26 PM2 5 PM 2 5 6 26 02_TW_3P697657 1 indd 24 3...

Страница 58: ...25 1 2 1 2 3 2 4 5 02_TW_3P697657 1 indd 25 30 Nov 22 3 45 21 PM...

Страница 59: ...26 24 1 25 2 1 25 2 4 3 3 1 10 15 3 2 6 3 PM2 5 PM 2 5 6 4 02_TW_3P697657 1 indd 26 30 Nov 22 3 45 22 PM...

Страница 60: ...27 1 14 2 3 25 4 02_TW_3P697657 1 indd 27 30 Nov 22 3 45 22 PM...

Страница 61: ...28 FAQ 4 12 3 02_TW_3P697657 1 indd 28 30 Nov 22 3 45 23 PM...

Страница 62: ...29 32 3 32 1 1 4 1 3 15 1 20 21 02_TW_3P697657 1 indd 29 30 Nov 22 3 45 25 PM...

Страница 63: ...30 AAA LR03 9 LCD AAA LR03 9 LCD AAA LR03 LCD 10 0 46 0 18 0 32 0 80 15 0 24 0 10 0 30 0 02_TW_3P697657 1 indd 30 30 Nov 22 3 45 25 PM...

Страница 64: ...31 3 02_TW_3P697657 1 indd 31 30 Nov 22 3 45 26 PM...

Страница 65: ...32 1 5 2 2 5 1 00 UA U0 U2 U4 A1 PCB A5 A6 C4 C9 CC EA E1 E5 E6 E7 E8 F3 F6 F8 H0 H6 H8 H9 J3 J6 L3 L4 L5 P4 02_TW_3P697657 1 indd 32 30 Nov 22 3 45 26 PM...

Страница 66: ...8 4 7 6 3 W 440 600 780 995 1370 COP W W 5 00 4 67 4 49 4 12 3 65 CSPF kWh kWh 6 82 6 47 6 68 6 37 5 96 CNS W 2700 3400 3800 4700 6000 kcal h 2320 2920 3270 4040 5160 A 2 7 3 7 4 0 5 0 7 1 W 540 750 8...

Страница 67: ...9 8 10 0 11 3 W 1580 2090 2120 2400 COP W W 3 80 3 44 3 77 3 63 CSPF kWh kWh 6 15 5 75 5 88 5 62 CNS W 7000 8000 9000 9500 kcal h 6020 6880 7740 8170 A 8 2 9 1 12 4 13 7 W 1740 1940 2640 2900 1 220V 6...

Страница 68: ...https www daikin com The two dimensional bar code is a manufacturing code 3P697657 1 M22N056 2211 HT 00_CV_3P697657 1 indd 2 31 Oct 22 2 57 18 PM...

Отзывы: